INSTALLATION 

SECTION 3

DIMENSIONS

MAXIMUM WORKING PRESSURE

MODEL

AC-65
AC-105  &  AC-125

HOSE  

FH-1

FH-1-1/2

PART NO.

83-0735 
83-0736

A

12"
16"

B

1" NPT

1-1/2" NPT

70

O

F

525 PSIG
450 PSIG

300

O

F

460 PSIG
395 PSIG

400

O

F

435 PSIG
370 PSIG

WEIGHT

2.0 LBS
3.0 LBS

FIGURE 3A FLEXIBLE HOSE

FIGURE 3B RECOMMENDED INSTALLATION

3.3 FLEXIBLE HOSE INSTALLATION

IMPORTANT

A FLEXIBLE HOSE MUST BE INSTALLED BETWEEN 

THE COMPRESSOR AND AFTERCOOLER TO 

VALIDATE THE WARRANTY ON THE AFTERCOOLER.

The flexible hose must be installed perpendicular to the direction 

of vibration from the compressor.  

If a flexible hose was not ordered with the aftercooler, one can 

be ordered from your Van Air distributor.  Figure 3A lists the 

hose required for each aftercooler model.

3.4 PIPING INSTALLATION

 

CAUTION

ALL PIPING MUST BE ADEQUATELY SUPPORTED AND 

ISOLATED FROM VIBRATION.  EXCESSIVE STRESS OR 

VIBRATION IN THE PIPING WILL CAUSE DAMAGE TO 

THE AFTERCOOLER CORE.

TO ENSURE PROPER OPERATION, MAKE SURE THAT 

THE INLET AND OUTLET PIPING ARE CORRECTLY 

CONNECTED TO THE UNIT.  REFERENCE FIGURE 2.2.

If the aftercooler is to be installed in an existing piping system, 

clean the piping to remove accumulated dirt, pipe scale, oil, and 

other contaminants before installing the unit.

A properly sized pressure relief valve should be installed after 

the compressor and before any block valves.  The relief valve 

should be installed in compliance with all applicable federal, 

state, and local codes.

To isolate the aftercooler for maintenance, install bypass piping 

around the aftercooler and separator (if installed).  Reference 

Figure 3B.

Connect the inlet piping to the inlet of the aftercooler, reference 

Section 2.2 for location.  Make sure that the flexible hose is 

properly installed before the aftercooler inlet.  Provide supports 

wherever necessary to prevent stress on the aftercooler.  

Supports should be installed close to the inlet and outlet 

manifolds.  Use either overhead or stiff-leg type supports.

Содержание AC-65

Страница 1: ...OVE THE RATED OPERATING CONDITIONS OPERATION ABOVE SPECIFIED CONDITIONS WILL RESULT IN DECREASED PERFORMANCE POSSIBLE DAMAGE TO THE UNIT AND OR PERSONAL INJURY NEVER OPERATE THIS AFTERCOOLER IF THERE...

Страница 2: ...C 105 AC 125 15 87 158 296 10 61 112 216 5 29 56 109 20 101 180 337 5 26 51 97 10 56 105 204 15 69 126 241 20 82 149 280 5 24 47 90 10 45 85 166 15 62 116 223 20 74 138 265 5 21 40 77 10 37 71 138 15...

Страница 3: ...THE AFTERCOOLER FROM VIBRATION IN THE PIPING REFERENCE Section 3 3 for instructions The location should be level and capable of supporting the aftercooler and all components and piping to be installed...

Страница 4: ...N IN THE PIPING WILL CAUSE DAMAGE TO THE AFTERCOOLER CORE TO ENSURE PROPER OPERATION MAKE SURE THAT THE INLET AND OUTLET PIPING ARE CORRECTLY CONNECTED TO THE UNIT REFERENCE FIGURE 2 2 If the aftercoo...

Страница 5: ...AL CODES IF THE AFTERCOOLER IS TO BE INSTALLED OUT DOORS OR IN AN EXTREMELY HUMID ATMOSPHERE MAKE SURE THAT ALL WIRING AND COMPONENTS ARE PROPERLY RATED VERIFY THAT THE POWER SOURCE MATCHES THE AF TER...

Страница 6: ...STIC CLEANERS CAUTION NEVER USE SOLVENTS CONTAINING STRONG ACID OR ALKALINE BASES TO CLEAN THE CORE DAM AGE TO THE CORE MAY OCCUR 4 3 SHUT DOWN To shut down the aftercooler turn off the electrical pow...

Страница 7: ...em 1 Dirty core or restricted air flow Inspect the core for deposits of dirt and or oils If the core is contaminated clean it as outlined in Sections 5 1 and 5 2 Check for obstructions around the afte...

Страница 8: ...ERs DANGER ELECTRICAL SHOCK FROM IMPROPER GROUNDING CAN CAUSE INJURY OR DEATH GROUND UNIT AND RELATED EQUIPMENT ACCORDING TO NATIONAL ELECTRICAL CODE AND LOCAL REGULATIONS WARNING WARNING READ THE OPE...