---34---
D. Instruments and controls
2.5.
Changing the Agroline tyre/tire parameters for
different tyres/tires
If the tyres/tires are changed to a different rolling diameter,
the instrument must be calibrated on the following way:
2
.8.1
69--- 25,92
If the setting mode is not altered for over 10 seconds, the
display changes into the normal mode.
--- With the power switched on press and hold the upper
side of change over switch for LCD---display unit (
2.8.1
)
for over 3 seconds. The display is in the setting mode
(minutes start to flash).
--- Press quickly the upper side of change over switch
(
2.8.1
), the letter
m
will start to flash.
--- Select the right code number by pressing the low side
of change over switch (
2.8.1
). By keeping the low side
pressed down the numbers change continuously.
Changing the parameters is complete when the display
goes into “normal” mode after about 10 seconds or by
pressing the upper side of the change over switch (
2.8.1
)
for over 3 seconds.
NOTE: The code number value can vary between
100 ---400. When pressing the switch rear edge, the
code value changes from a smaller value to greater
one. The code numbers and corresponding tyres/tires
are listed in the table on the page 107.
D 2.2.2.9.
Change over switch for LCD---display unit
in Agroline instrument panel (2
.8.1
)
2
.8.1
69--- 25,93
The operation of change over switch for LCD---display unit
is explained under “LCD---display unit” starting on
page 32.
D 2.2.3.
Side panel of instrument panel (3)
D 2.2.3.1.
Ignition switch (3
.1
)
3
.2
3
.4
3
.1
3
.3
3
.5
69--- 25,94
Starter switch positions:
Stop, motor (symbol 0 on models with STOP
control)
1
Power on (normal position for running the engine,
which also allows the electrical equipment to be used
when the engine is not running)
Glow position for pre---heating the induction air.
Starting position
D 2.2.3.2.
Switch, fan (3
.2
)
The fan has two speeds.
D 2.2.3.3.
Heater control (3
.3
)
The amount of heat is increased by turning the knob
clockwise. In summer the heater unit can be used as cab
ventilator by closing off the coolant circulation.
The amount of heat from the roof heater fans (extra
equipment) is also controlled by this knob.
D 2.2.3.4.
Hand throttle lever (3
.4
)
--- Full throttle position (lever in rear position)
--- Idling position (lever in front position)
D 2.2.3.5.
Ventilation nozzle (3
.5
)
The ventilation nozzles are on both side panels.
Содержание 600
Страница 1: ...Operator s manual 600 900...
Страница 12: ...11 B Safety precautions 1 2 1 HiShift is optional equipment 2 Electrohydraulically controlled hydraulic lift...
Страница 111: ...110 J Specifications J 13 Wiring diagram component list on pages 108 109 33202000O 69 1 69 2...
Страница 112: ...111 J Specifications Wiring diagram component list on pages 108 109 69 3 69 4...
Страница 113: ...112 J Specifications Wiring diagram component list on pages 108 109 69 5...
Страница 142: ...Ref no 39 179 21 9 11 2002 Printed in Finland by Kopijyv English...