TROUBLE SHOOTING CHART

 

FAULT 

POSSIBLE REASON 

SOLUTION 

Continuous steam discharge

 

Damaged seat. 
 
 
Incorrect installation. 

 
Substitute seat. 
 
check the installation position 
(see IMI 1.344 E 08.03). 
 

The condensate isn’t discharged 
Or not enough discharged 

 
Obstructed strainer. 
 
 
 
Inadequate pressure differential. 
 
 
 
Excessive back pressure. 
 
 
Damaged float. 
 

 
Proceed to an accurate clean and 
identify the possible reason of 
contamination. 
 
Check the steam trap D.P. and 
substitute. 
 
 
Replace the steam trap by a 
superior DN or use ADCAMAT. 
 
Replace. 

 
Temporary condensate 
accumulation 
 

Steam blocking. 
 
Downsizing. 

 
Use a steam trap with SLR. 
 
Check maximum flow rate (during 
start-up) 

Slow initial start up 

 
Damaged air eliminator. 
 
The air flow is too high for the trap. 
 
Downsizing. 

 
Replace. 
 
Install an additional air eliminator. 
 
Check maximum flow rate (during 
start-up) 

 

 

SPARE PARTS  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P O S.Nr .

DESIG NATIO N

M ATERIAL

1

Body

CF8M / 1.4408

2

Cover

CF8M / 1.4408

3

*Gas ket

Stainless  s t./Graphite

4

*Seat

A ISI 410 / 1.4006

5

*V alve 

A ISI 440C / 1.4125

6

*Lever

A ISI 304 / 1.4301

7

*Float

A ISI 304 / 1.4301

8

*A ir vent

Stainles s st. (Bimetallic)

9

Bolts

St.Steel A 2-70

FTL14I DN15-20 PARTS

*A vailable spare parts.

Содержание FLT14I Series

Страница 1: ...t be carried out by trained personnel A supervisor must follow and check all activities For the problems that cannot be solve with the help of this instructions please contact the supplier or the manu...

Страница 2: ...advised to assess the risks taking into account the task the individual the load and the working environment Before starting work ensure that you have suitable tools and or consumables available Use...

Страница 3: ...p maintenance The by pass must be kept close during the normal operation Procedure Prior to install check that the product is suitable for the intended application materials and pressure temperature r...

Страница 4: ...up it is recommended to check pipe connections for leaks and retighten the connections if necessary MAINTENANCE We recommend the steam traps to be serviced as necessary Steam traps should be checked...

Страница 5: ...reason of contamination Check the steam trap D P and substitute Replace the steam trap by a superior DN or use ADCAMAT Replace Temporary condensate accumulation Steam blocking Downsizing Use a steam...

Страница 6: ...ARTS Available spare parts POS Nr DESIGNATION M ATERIAL 1 Body CF8M 1 4408 2 Cover CF8M 1 4408 3 Gasket Stainless st Graphite 4 Seat AISI 410 1 4006 5 Valve AISI 440C 1 4125 6 Lever AISI 304 1 4301 7...

Страница 7: ...of contaminating fluids and residues or mechanical damage that may represent a health safety or environmental risk must be provided in writing by the distributors and costumers when returning products...

Отзывы: