background image

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

5

BEFORE OPERATION

1

2

3

5

WARNING

WARNING:  do  not  use  a  pipe  carrying 

combustible  material  as  the  ground 

source. 

Generator Ground Terminal

GROUNDING THE GENERATOR

The  National  Electric  Code  requires  that  this  product 

be properly connected to appropriate earth ground to 

help  prevention  of  electric  shock. A  ground  terminal 

connected  to  the  frame  of  the  generator  has  been 

provided for this purpose. Connect a heavy gauge (12 

AWG min.)  bare copper cable between the ground lug 

attached to the generator frame (identified with a label 

with the ground symbol- see figure below) and a cooper 

rod drawn 1 meter into the ground which should provide 

a  suitable  ground  connection.  However,  consult  with 

a local electrician to insure that local codes are being 

adhered to.

ELECTRIC EXTENSIONS OR CORDS

All generator loads will be connected from the control 

panel with extensions or cords with 3-prong grounded 

plug  for  connection  to120  volts  outlet  and  4-prong 

grounded plug for connection to 120/240 volts outlets.

See Table 3 for selection of the minimum cable gauge 

of  extensions  or  cords  in  agreement  with  the  loads 

requirements.     

When the load increases a cable extension of greater 

size must be used. Using extensions of inadequate size 

can result in serious problems with the voltage, reducing 

the  electric  energy  applied  to  the  tools  and  causing 

damage on them. 

As far as smaller is the number of the wire gauge ,greater 

is the conduction ampacity, for example, a gauge 14 

wire can carry a current higher than that a gauge 16 

wire can. 

When several extensions are connected it is a must to 

review that each extension is of the minimum gauge 

required.

1

2

3

4

5

Connect a bare # 12 AWG 

copper cable from the 

ground terminal to an earth 

grounding point

4

CAUTION

Do  not  overfill  the  tank.  Keep  maximum 

fuel level ¼ inch below the top of the tank. 

This will allow fuel expansion during warm 

weather, and so, avoid spillage.

LUBRICATION

DO NOT attempt to start the engine without filling the 

engine crankcase with the proper amount and type of 

oil. Use SAE 10W-30 oil.

Your  generator  has  been  shipped  from  the  factory 

without oil in the engine crankcase. Operating the unit 

without oil may damage the engine and will be cause of 

warranty loss.

Fill the engine according to the engine manual. In this 

engine the plastic plug of the engine crankcase is the oil 

fill and check plug.Fill with oil and check the level using 

the marks in the dipstick.

LOW OIL SENSOR

The engine is equipped with an oil sensor. If the oil level 

becomes lower than required, the sensor will activate

a  warning  device  and  stop  the  engine  (see  the 

accompanying engine manual for more information).

If  the  generator  turns  off  and  the  oil  level  is  within 

specifications, check that the generator is not placed at 

an angle that forces the oil level to change. Place the 

generator on an even surface to correct this problem. 

If the engine does not start, the oil level could not be 

enough to shut off the automatic “low oil” switch. Make 

sure the dipstick indicates the correct level.

Engine

Oil dipstick

Fuel tank Valve

Choke

OFF - ON

Throttle

FAST

ON

Throttle and Choke position for starting engine

the installation of any item that concerns this product.

1. NFPA 70 – National Electrical Code.

2.  NFPA  37  –  Standard  for  Installation  and  Use  of 

Stationary Combustible Engines.

3. Agricultural  Wiring  handbook  of  Farm  Standby 

Electric Power.

FUEL

Fill the tank with unleaded fuel, clean and new.  You can 

use regular-grade fuel as long as it has a high octane 

value (at least 85 octane). Always use a fuel additive. 

A  fuel  additive  will  minimize  the  development  of  fuel 

gum deposits during storage.  The fuel additive can be 

added to the fuel into the gas tank or put together to the 

fuel in a storage container.   The fuel and engine smoke 

are flammable and potentially explosive. Use a suitable 

procedure to store and handle fuel. Always have an ABC 

fire extinguisher nearby.

Содержание G8000 PRO

Страница 1: ......

Страница 2: ...placement parts SAFETY INFORMATION DANGER indicates a potentially hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous situation wh...

Страница 3: ...when it is running Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose loose or missing clamps or damaged tank or cap All defects should be corrected b...

Страница 4: ...of voltage and 3 Hz of the rated values marked in the generator nameplate To avoid damage always have an additional no solid state load plugged into the generator if only solid state equipment such as...

Страница 5: ...he tank This will allow fuel expansion during warm weather and so avoid spillage LUBRICATION DO NOT attempt to start the engine without filling the engine crankcase with the proper amount and type of...

Страница 6: ...n one electric tool sum the amperes marked in the nameplates of each tool to determine the minimum cord gauge you need to use The extensions for 120 volts are made of 3 conductors where the green one...

Страница 7: ...rea immediately get fresh air and SEEK MEDICAL TREATMENT To prevent serious injury or death from carbon monoxide NEVER run engine indoors Even if you try to ventilate the engine exhaust with fans or o...

Страница 8: ...ble of the spark plug if engine is of electrical start before any inspection or maintenance Before each use review the general conditions of the generator Review that all pieces are complete Review if...

Страница 9: ...RFORM BY ITSELF ANY PARTS REPLACEMENT OR REPAIRS TO THE PRODUCT ON PRINCIPLE BUYER AND OR END USER IS CONSIDERED BY THE MANUFACTURER UNQUALIFIED TO PERFORM BY ITSELF ANY REPAIRS OR PARTS REPLACEMENT T...

Страница 10: ...HOUT NOTICE 10 ALTERNATOR SPARE PARTS NOTE Some parts are shown for illustration purposes only and are not available individually as replacement parts NOTE only a licensed electrician should perform e...

Страница 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 ASSEMBLY G80...

Страница 12: ...r higher unleaded gasoline A funnel must be used to avoid gasoline spills near hot areas It is recommended to pour no more than 6 gallons of gasoline due to gases produced by gasoline when exposed to...

Страница 13: ...nar el motor a velocidades demasiado altas Si se opera el motor a excesiva velocidad aumenta el riesgo de lesiones f sicas No toque o cambie piezas que puedan aumentar o disminuir la velocidad regulad...

Страница 14: ...lido debe utilizarse un protector de sobrecarga para evitar posibles da os al equipo No coloque nada a trav s de las ranuras de ventilaci n a n cuando el generador no est en operaci n Esto puede da ar...

Страница 15: ...determinadas condiciones Servicio continuo significa operaci n por periodos de unas cuantas horas en un evento no 24 horas al d a durante d as Tambi n implica alimentar una carga con FP unitario carg...

Страница 16: ...n ngulo que force al nivel de aceite a cambiar Coloque el generador en una superficie plana y horizontal para corregir el problema Si el generador no arranca el nivel de aceite pudiera no ser suficien...

Страница 17: ...nductores en donde el conductor verde es el conductor de la espiga de tierra el conductor blanco es la conexi n al neutro del generador y el conductor negro es el conductor vivo Las extensiones para s...

Страница 18: ...un gas letal inodoro e invisible que se puede presentar aunque usted no vea o huela ning n escape de motor Niveles mortales de mon xido de carbono se pueden agrupar rapidamente y usted puede perder ha...

Страница 19: ...intente realizar algunos de estos f ciles pasos antes de llamar a la l nea directa de informaci n de servicio al cliente Verifique el nivel de aceite Reemplace el combustible viejo Cambie la buj a de...

Страница 20: ...o de la buj a tire del retr ctil varias veces y coloque la buj a Luego tire del arrancador hasta que sienta que el pist n esta en su carrera de compresi n y d jelo en esta posici n Esto cierra las v l...

Страница 21: ...RIO FINAL EST AUTORIZADO PARA USAR ESTA INFORMACI N COMO BASE PARAEFECTUAR POR S MISMO CUALQUIER REEMPLAZO DE PARTES O REPARACI N AL PRODUCTO EN PRINCIPIO EL FABRICANTE CONSIDERA AL COMPRADOR Y O USUA...

Страница 22: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 22 EXPLOSIVO GENERAL...

Страница 23: ...temente Repita este procedimiento si es necesario Llene el tanque de 25Lcon gasolina sin plomo limpia y nueva de 85 octanos o superior Use un embudo para este proceso Se recomienda no exceder la canti...

Страница 24: ...Call 888 ready 19 888 73239 19 Nationwide Service Centers Manufactured under specs of 9163 Siempre Viva Road San Diego CA 92154 www valsi net Manufactured in Mexico...

Отзывы: