manualshive.com logo in svg
background image

11

Air Diverter 

Plate

Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct 
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option 
is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal fi lters are required on top of its standard mesh 
fi lter set. Order according to its part number below. The standard mesh fi lters are intended to capture residue 
from cooking and the optional charcoal fi lters help to purify fumes exhausted from cooking for recirculation.   

RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)

Kit includes charcoal fi lters, brackets and air diverter plate.

Hood Models 

    Part No. 

          Filters & Brackets in pkg.                         

VLT-E36AS 

    VRC-00LT 

 

 

         2                                    

VLT-E42AS             VRC-01LT   

 

         3

1.   Purchase recirculating kit per the part number above

2.   Secure air diverter plate to top support frame (FIG. H) Open sides of air 

diverter plate should face left and right to direct air through the louver holes 
located on the top duct cover.  Run 6” ducting from top of hood and secure 
to air diverter plate. 

3.  Remove aluminum mesh fi lters from hood. Secure charcoal fi lter brackets 

to the hood body behind each mesh fi lter using the screws included with 
the recirculating kit. Clip charcoal fi lters onto each charcoal fi lter bracket. 
(FIG. J) 

4.   Re-Install mesh fi lters.

 

Charcoal fi lters must be replaced after every 120 hours of use (or 
approximately every 3 to 4 months based on an average of 1 - 2 hrs. 
of daily cooking time).

NOTE: For more details refer to manual included with 
recirculating kit.

Charcoal Filter Replacements

Hood Model 

 

Part No. 

          Qty to Order

VLT-E36AS 

 

V0F-C002   

   1                        

VLT-E42AS 

                         V0F-C002                     2

DO NOT WASH CHARCOAL FILTERS.  Charcoal fi lters may need
to be changed more often depending on cooking habits.

Installation – 

Ductless Recirculating

FIG. J

FIG. H

Содержание VLT-E36AS

Страница 1: ...Use Care and Installation Guide Model number Serial Number Lateral Island VLT E36AS VLT E42AS JUN11 0101...

Страница 2: ......

Страница 3: ...eight Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 10 Ductless Recirculating 11 FEATURES CONTROLS Electronic Controls 12 MAINTENANCE Hood and Filter Cleaning 13 Light Bulbs...

Страница 4: ...of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or me...

Страница 5: ...is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes...

Страница 6: ...CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Hack saw to cut down trim pieces Cable connector if required by local codes Duct cover extension accessory V1C 00LT Recirculatin...

Страница 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 8: ...ose performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any diff...

Страница 9: ...e ducted to the outside unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Du...

Страница 10: ...d Specifi cation CL 35 7 8 41 7 8 14 3 15 16 26 7 8 STANDARD min ducted 28 min recirc 30 max 41 V1C 00LT EXTENSION min ducted 50 1 2 min recirc 54 1 2 max 79 12 4 5 8 2 3 16 6 Top 12 3 8 9 1 2 12 3 16...

Страница 11: ...word front on the top support frame faces the front of the hood where the controls will be located FIG D The key holes on the top support frame should cover the wood screws previously installed in the...

Страница 12: ...FIG F2 9 Assemble Bottom Duct Covers together over top duct covers using the final 6 M3 x 5 screws 3 screws on each side of the duct cover FIG F3 Bottom Duct Covers should rest on top of the Hood Body...

Страница 13: ...UIRED IF NO DUCTING IS USED Kit includes charcoal filters brackets and air diverter plate Hood Models Part No Filters Brackets in pkg VLT E36AS VRC 00LT 2 VLT E42AS VRC 01LT 3 1 Purchase recirculating...

Страница 14: ...Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Brig...

Страница 15: ...oth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out...

Страница 16: ...e by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the included glass suction cup...

Страница 17: ...e defective part The unit is vibrating 1 The motor is not secured in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the insta...

Страница 18: ...16 Wiring Diagrams...

Страница 19: ...each Z0B 0020 Optional Accessories Recirculating Kit VLT E36AS VRC 00LT Recirculating Kit VLT E42AS VRC 01LT Replacement Charcoal Filters Qty 2 V0F C002 Extension Duct Cover V1C 00LT Order replacement...

Страница 20: ...labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE F...

Отзывы: