Operating and Installation
Instructions

Ventilation System
DA 211
DA 217-3
DA 218
DA 219-3

To prevent accidents
and machine damage,
read these instructions

before

installation or use.

UV

M.-Nr. 05 802 950

Summary of Contents for DA 211

Page 1: ...Operating and Installation Instructions Ventilation System DA 211 DA 217 3 DA 218 DA 219 3 To prevent accidents and machine damage read these instructions before installation or use UV M Nr 05 802 950 ...

Page 2: ...2 ...

Page 3: ...ing and Care Cleaning the casing 16 Grease filters 17 Active charcoal filters 18 Changing the light bulb 19 After Sales Service Installation instructions Caring for the environment Installation accessories Plywood backing Electrical data Appliance dimensions Installation Retaining plates 32 Attaching the canopy 34 Inserting the non return flap 35 Electrical connection 36 Air extraction exhaust con...

Page 4: ...ctrical safety of this appliance continuity must exist between the appliance and an effective grounding system It is imperative that this basic safety requirement be met If there is any doubt have the electrical system of the house checked by a qualified electrician The manufacturer can not be held responsible for damages caused by the lack or inadequacy of an effective grounding system Before con...

Page 5: ...not allow children to play with or operate the appliance or its controls Supervise its use by the elderly or infirm Be careful when preparing a flambé beneath the hood Flames may be drawn up into the hood by the suction or grease filters may catch fire Never operate gas burners without pots Do not leave cooking surfaces unattended while in use Overheated food oil and grease can catch fire Do not u...

Page 6: ...OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explo...

Page 7: ...ion cords do not guarantee the required safety of the appliance e g danger of overheating Do not install this hood over cooktops burning solid fuel Any fittings sealant or materials used to install the ductwork must be made of approved non flammable materials Never connect an exhaust hood to an active chimney dryer vent vent flue or room ventilating ductwork Seek professional advice before connect...

Page 8: ...Guide to the appliance 8 ...

Page 9: ...r timer after cleaning the grease filters see Cleaning and Care to show how long the grease filters have been in use see Operation Filter timers to change the number of hours counted by the grease filter timer see Operation Reprogramming the filter timers n Charcoal filter button used in recirculation mode only The indicator above the charcoal filter button lights when the charcoal filters need to...

Page 10: ...occur When the hood is turned on the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside Recirculation mode Air is drawn through the grease filters and an active charcoal filter The filtered air is then recirculated back into the kitchen through a vent at the top of the hood s chimney Before using the hood in recirculation mode ensure that ...

Page 11: ...ve setting Level 4 yellow indicator should be used for a short period when frying or cooking food with a strong aroma Fan performance The maximum air flow capacity is 625 cfm Factors such as narrow duct diameter and bends will affect this value There will also be a slight decrease in airflow for hoods operated in recirculation mode due to the active charcoal filter Level 1 operates at 40 capacity ...

Page 12: ... was activated The lighting however will remain on Press the On Off button to turn the fan back on again Turning the lighting on off The overhead lighting can be turned on and off independently of the fan Press the light button briefly to turn on the lighting The light button indicator illuminates Press the light button briefly again to turn off the lighting The light button indicator will go out ...

Page 13: ...ter timer The charcoal filter indicator will light once the selected time has elapsed The charcoal filters must then be replaced and the charcoal filter timer must be reset To do this press the charcoal filter button for about 3 seconds The indicator will go out Checking the filter timers To check the percentage of time already used Press the On Off button to turn the fan on Press the grease or ch...

Page 14: ...mming the grease filter timer Press the On Off button to turn off the fan Press the Delayed Shut Down and grease filter buttons at the same time The indicator for the grease filter and one of the _ indicators will flash The lit indicator shows the programmed time 1st indicator from the left 20 hours 2nd indicator from the left 30 hours 3rd indicator from the left 40 hours 4th indicator from the le...

Page 15: ...nd Charcoal Filter buttons at the same time The indicator for the charcoal filter and one of the _ indicators will flash The lit indicator shows the programmed time 1st indicator from the left 20 hours 2nd indicator from the left 30 hours 3rd indicator from the left 40 hours 4th indicator from the left 50 hours Use the or button to select the desired time Store the selection by pressing the charco...

Page 16: ...ls Water could penetrate into the electronics and cause damage Avoid cleaning agents containing soda acids or chlorides abrasive cleaning agents e g powder or cream cleansers abrasive sponges e g pot scourers or sponges which have been previously used with abrasive cleaning agents These will damage the surface Stainless steel Stainless steel surfaces can be cleaned using a non abrasive stainless s...

Page 17: ... permanent discoloration of the filter surface Performance of the filter will not be affected by this discoloration After cleaning the filters can be placed on a towel to air dry While the filters are removed clean any dirt or grease from the filter casing to prevent the risk of fire When putting the grease filters back make sure that the locking clips are visible facing down towards the cooking s...

Page 18: ...lters Follow the instructions supplied with the active charcoal filters Replace the active charcoal filters when the charcoal filter indicator lights Replace the filters at least every 6 months or when they no longer absorb odors efficiently After replacing the charcoal filters press and hold the charcoal filter button for about 3 seconds to reset the charcoal filter timer The indicator light will...

Page 19: ...bulbs until they have had sufficient time to cool down Do not touch the bulb surface Fingerprints or body oils deposited on the bulb will decrease the life of the bulb Follow the bulb manufacturer s instructions To change the halogen bulb first remove the lamp cover a Pull the bulb b out of its socket and replace with a new one Return the lamp cover a Never use the lighting without the lamp cover ...

Page 20: ...al Service Department USA 1 800 999 1360 techserv mieleusa com CDN 1 800 565 6435 service miele ca When contacting the Technical Service Department please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filter is removed After Sales Service 20 ...

Page 21: ...Installation Instructions ...

Page 22: ...22 ...

Page 23: ...ren ensure that any plastic wrappings bags etc are disposed of safely and kept out of their reach Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Before discarding an old hood unplug it from the outlet and cut off its power cord to prevent hazards Caring for the e...

Page 24: ...Installation accessories 24 ...

Page 25: ... flap for vented air extraction only i Upper retaining plate B secures the chimney extension j Middle retaining plate C for additional stability of the chimney k Lower retaining plate A secures the canopy and motor assembly 12 large headed screws 5 x 40 mm for securing the retaining plates and the canopy S8 wall anchors included in the packaging are not for use in USA CDN 2 M 6 locking nuts for se...

Page 26: ...plate A against the wall so that the marks are visible through the holes of the plate see Installation Retaining plate A Draw a line around the plate s perimeter then set aside the plate Make a cutting line 3 76 mm above and 3 76 mm below the outline of plate A Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line alon...

Page 27: ...d the grease filters match the household electrical supply before installing the hood If there is any question concerning the electrical connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department USA 1 800 999 1360 CDN 1 800 565 6435 WARNING THIS APPLIANCE MUST BE GROUNDED Important The hood comes equipped with a 5 ft 1 5 m ...

Page 28: ...Appliance dimensions 28 ...

Page 29: ...edures and determine height S before beginning the installation Installation producers differ depending on the model and venting method If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than appliance height H Standard unit height H DA 211 Extraction 29 1 8 38 9 16 740 980 mm Recirculation 32 11 16 41 15 16 830 1065 mm DA 217 3 E...

Page 30: ... 980 mm 32 11 16 41 15 16 830 mm 1065 mm DATK 217 219 605 38 9 16 48 980 mm 1220 mm 42 51 3 16 1066 mm 1300 mm DATK 217 219 840 48 57 1 2 1220 mm 1460 mm 51 3 16 60 1 2 1300 mm 1536 mm DA 217 3 Extraction Recirculation Standard unit H 28 37 3 8 710 mm 950 mm 31 1 2 40 3 4 800 mm 1035 mm DATK 217 219 605 37 3 16 46 7 16 945 mm 1180 mm 40 3 4 50 1035 mm 1270 mm DATK 217 219 840 46 7 16 55 11 16 1180...

Page 31: ...75 mm DATK 217 219 840 47 56 1 2 1195 mm 1435 mm 50 3 16 59 1 2 1275 mm 1511 mm DA 219 3 Extraction Recirculation Standard unit H 28 3 4 38 3 16 730 mm 970 mm 32 5 16 41 9 16 820 mm 1055 mm DATK 217 219 605 38 3 16 47 5 8 970 mm 1210 mm 41 9 16 50 13 16 1056 mm 1290 mm DATK 217 219 840 47 5 8 57 1 16 1210 mm 1450 mm 50 13 16 60 1 16 1290 mm 1526 mm Appliance dimensions 31 ...

Page 32: ...y be used if the distance between plate A and plate B is greater than 14 3 8 365 mm Attaching the retaining plates to the wall Before fitting the retaining plate draw a vertical line centrally above the cooktop on the rear wall Mark measurement S from the cooktop surface upwards see Appliance dimensions This marks the height of the lower rim of the hood Installation 32 ...

Page 33: ...otches to align with the center line Drill 4 more 1 8 3 mm holes through the now fitted retaining plate Screw two 5 x 40 mm screws into the upper two holes Retaining plate B Hold retaining plate B to the wall and push up until it is directly below the ceiling Use the notches and the center line to align it horizontally Mark the 2 drill holes on the wall Drill two 1 8 3 mm holes into the wall Secur...

Page 34: ... 365 mm from the ceiling hold retaining plate C against the wall and use the notches to align it with the center line Mark the two drill holes Drill two 1 8 3 mm holes into the wall Secure retaining plate C with two 5 x 40 mm screws Attaching the canopy Hang the canopy on the angled brackets on retaining plate A Secure the canopy with 5 x 40 mm screws into each drilled hole Installation 34 ...

Page 35: ... 5 125 mm exhaust ducting is used the reducing collar must be fitted into the exhaust connection on the motor see Air extraction Recirculation mode The non return flap is not required Attaching the motor assembly First loosely screw the two locking nuts onto the threaded bolts on retaining plate A Leave a gap of 1 8 3 mm for hanging the motor on Fit the motor assembly onto the hooks on retaining p...

Page 36: ...receptacle left of the motor assembly Insert the 6 prong connector into the receptacle right of the motor assembly Secure the cords with the ties as shown above Plug in the power cord Air extraction exhaust connection Connect the ductwork to the exhaust connection using whatever means are appropriate for the type of ductwork being installed hose clamp duct tape etc Direct the duct through the back...

Page 37: ...uilding is not possible Slide the diverter on to the brackets of plate B Slip the hose clamps over the flex hose onto the diverter and the motor assembly exhaust connection Once in place tighten the hose clamps Active charcoal filters must be used in the recirculation mode Installation 37 ...

Page 38: ...st be intalled in relationship to the method of venting Extraction or Recirculation Recirculation Air extraction The extension piece has vented openings on one end These vents are required for recir culation mode and will be closest to the ceiling when installed For air extraction the vents are not required and are covered by the chimney Installation 38 ...

Page 39: ...nd snap over the upper retaining plate B When installing for recirculation ensure that the vents are positioned so they line up with the diverter Screw the extension piece firmly to the upper retaining plate using two 3 9 x 7 5 mm screws Cover the screws with the supplied cap covers Only for recirculation With the slats pointing downwards install the recirculation vents through the extension piece...

Page 40: ...shield to the chimney extension so that it is smooth and flush with the bottom Remove the protective foil from the chimney Remove the backing from the adhesive strips on the protective shield Attach the protective shield to the front of the chimney so that it protrudes slightly below the bottom edge Installation 40 ...

Page 41: ...plate A Remove the protective shields If the chimney is not tall enough an optional chimney extension can be ordered See Installation Appliance dimensions Secure the chimney to reatining plate A on both sides with two 3 9 x 7 5 mm screws Remove the protective foil from the canopy Before using the appliance remove the grease filter and remove the protective foil from the filter frame Return the fil...

Page 42: ...ng should be as short and straight as possible and the number of sharp bends should be minimized For most efficient air extraction the diameter of the ductwork should not be less than 6 150 mm Use of flat ducts also reduces the air extraction efficiency Noise levels of the hood will increase if flat ducts or round ducts of less than 6 150 mm in diameter are used Use smooth or flexible pipes made f...

Page 43: ...od vent to an existing inactive chimney or vent flue Condensate trap Important If the ductwork runs through rooms ceilings garages etc where temperature variations exist it may need to be insulated to reduce condensation In some cases a condensate trap may also be required to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertica...

Page 44: ...M Nr 05 802 950 00 Alteration rights reserved 1703 This bio friendly paper was bleached without the use of chlorine ...

Reviews: