Page 1: ...Installation instructions and how to use and look after your built in cooker hoods NEFF UK Ltd ...

Page 2: ...Abb 1 ELECTRO Fig 1 GAZ min 650 min 550 2 ...

Page 3: ... installation 7 Operating modes 8 Exhaust air mode 8 Circulating air mode 8 Operation 9 Cleaning and Care 10 Removing and installing the grease filters 11 Removing and installing the metal mesh grease filters 11 Installing and removing the activated carbon filters 11 Changing the bulbs 12 Installation instructions 13 Connecting Pipes 13 Electrical Connections 14 Installation 15 Installation prepar...

Page 4: ...rials can be reclaimed by recycling old appliances This appliance is identified according to the European Directive 2002 96 EC on waste electrical and electronic equipment WEEE The directive specifies the framework for an EU wide valid return and re use of old appliances Before disposing of your old appliance render it unusable Never treat your old appliance as non recyclable waste Please ask your...

Page 5: ...ustomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isolate the extractor hood by pulling out the mains plug or switching off the fuse Safety instructions If the appliance is improperly installed serviced or repaired the user may be placed in considerable ...

Page 6: ...obs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the gas appliance manufacturer During installation ensure that only one side of the extractor hood is situated directly next to a high sided unit or a wall Otherwise there is a risk of heat build up The gap between...

Page 7: ...d if you are cooking food with oils or fats e g chips Overheated oils or fats can easily ignite A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated carbon filter in good time Never operate the extractor hood without grease filters Correct installation Check the manufacturer s specifications for the cooker to determine whether an extractor hood can be...

Page 8: ...ust be connected and switched off Simultaneously press buttons and r until ã is displayed Repeatedly press buttons and r to switch the electronic control back to exhaust air mode by display The extractor hood can be used in exhaust air and circulating air mode The standard setting is exhaust air mode Exhaust air mode The air which is drawn in is cleaned by the grease filters and conveyed to the ex...

Page 9: ...off by hand the fan automatically switches back to setting 2 after 10 minutes Fan run on Press button r The fan runs for 10 minutes at the selected setting The r symbol is lit on the display Then the fan switches off automatically Light The light can be switched on and off independently of the fan To adjust the luminosity hold down button 0 until the required luminosity is obtained Saturation disp...

Page 10: ...ease particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The function of the extractor hood may also be impaired The risk of fire is prevented by cleaning the metal mesh grease filters in good time When cleaning the grease filters also remove grease deposits from the accessible...

Page 11: ... be replaced approximately 2x year The activated carbon filter is available from specialist outlets customer service or the Online Shop see Optional accessories Use original filters only Activated carbon filters do not contain any pollutants They can be disposed of in the household refuse Before removing and installing the grease filters always follow the instructions and warnings in the chapter e...

Page 12: ...uch the glass tube Therefore use a clean cloth when inserting the bulb 3 Close the inner frame of the halogen bulb NOTE The inner frame of the halogen bulb will not close unless it was fully opened beforehand 4 Restore the power supply by inserting the mains plug or switching on the fuse NOTE If the light does not function check whether the bulbs have been inserted correctly Before changing the bu...

Page 13: ... rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses made of non combustible material for installation of the exhaust air duct The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pip...

Page 14: ...required connection data can be found on the rating plate inside the appliance when the grease filters have been removed Length of the power cord approx 1 30 m This extractor hood complies with the EC interference suppression regulations ELECTRICAL CONNECTION Before connecting the appliance to the power supply always follow the instructions and warnings in the chapter entitled Safety instructions ...

Page 15: ... bearing capacity Ensure that the depth of the drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight in kg 40 Design subject to modification in line with technical development Installation preparations 1 Mark a centre line on the wall from the ceiling to the lower edge of the extractor hood 2 Using the enclosed template mark positions for the scre...

Page 16: ...1 Mark the holes for the safety screws Detach the extractor hood drill holes for the safety screws and press in wall plugs flush with the wall 2 Attach the extractor hood and screw in the safety screws tightly 3 Press the safety caps with the arrow upwards onto the brackets until they click into position Ⓒ RISK OF INJURY Check that all locking screws and locking caps have been attached securely 4 ...

Page 17: ...wearing protective gloves during installation 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective film from both flue ducts 3 Insert one flue duct into the other NOTE Avoid scratching the flue ducts when inserting them e g by placing the installation template as protection over the edge of the outer flue duct Note the position of the slots in the flue duct Exhaust...

Page 18: ...18 Notes ...