background image

\}‹†}ŠD‹Œ‘„}{€…†}‘€‡‡|‹

c\Gc\]eGc\meQOHHFHGQPHHFH

\}‹†}ŠD‹Œ‘„}‹„y†|€‡‡|‹

ac\Gac\]eGac\meIHOHHFHGIHPHHFH

Summary of Contents for IKD 10700.0

Page 1: ... D c Gc eGc me QOHHFHGQPHHFH D y ac Gac eGac me IHOHHFHGIHPHHFH ...

Page 2: ...ce Manual H5 60 69 01 Responsible U Laarmann KÜPPERSBUSCH HAUSGERÄTE AG Email uwe laarmann kueppersbusch de Tel 0209 401 732 Kundendienst Fax 0209 401 743 Postfach 100 132 Date 31 10 2003 45801 Gelsenkirchen ...

Page 3: ...KDUM 6 3 2 KD KDEM KDUM 8 4 Accessing the components 10 4 1 IKD IKDEM IKDUM 10 4 2 KD KDEM KDUM 14 5 Charcoal filter 16 6 Grease filter 16 7 Operating unit 17 8 Lighting 17 9 Technical data and circuit diagrams 18 9 1 Technical data 18 9 2 Wiring plans 19 10 Finding faults 21 11 Air extraction rate dB data in accordance with EN 22 ...

Page 4: ...must be used at all times The ground wire resistance must not exceed that specified in the standard It is of vital importance for ensuring the safety of people and the functioning of the appliance On completion of repairs an inspection must be carried out in accordance with VDE 0701 Association of German Electrical Engineers or the corresponding regulations for your country Caution Make sure you o...

Page 5: ...tions carefully 3 Exhaust air may not be discharged into a smoke or exhaust gas chimney which is in operation nor may it be discharged into a shaft used for ventilating rooms where hearths or fireplaces have been installed Should exhaust air be discharged into smoke chimneys or exhaust gas chimneys which are not in operation prior approval must be granted by the master chimney sweep responsible 4 ...

Page 6: ...6 H5 60 69 01 For internal use only 3 Mounting instructions 3 1 IKD IKDEM IKDUM ...

Page 7: ...H5 60 69 01 7 For internal use only ...

Page 8: ...8 H5 60 69 01 For internal use only 3 2 KD KDEM KDUM ...

Page 9: ...H5 60 69 01 9 For internal use only ...

Page 10: ...een loosened the operating element can be removed towards the back above the grease filter To replace it use the mounting aid spare part no 340287 2x Please proceed as follows Insert the two threaded rods from the outside through the drilled holes of the operating element onto the casing and screw onto the operation element Then by means of pulling up the two threaded rods guide the operation elem...

Page 11: ... the motor screws and remove the motor towards the top It may be necessary to remove the electronics unit In order to do so the motor should still be installed In order to remove the electronics unit see too 4 1 3 Electronics unit remove the two screws and pull out the two group sockets You will then be able to pull the unit out towards the front 4 1 3 Electronics unit In order to remove the elect...

Page 12: ...10800 0 GE The cooker hood must be removed in order to replace the glass canopy Subsequent to removing the cooker hood remove the two group sockets from the electronics unit and place the appliance on the motor support Remove the grease filter and if present the charcoal filter Remove the four screws that connect the bottom part including the glass canopy to the motor casing Remove the bottom part...

Page 13: ...In order to replace the halogen lamps 2x 20 W Type G4 clip out the glass cover with a screw driver and remove the halogen lamp from the plug base Use a cloth to insert the new halogen lamp Do not touch the lamps with your fingers Finally replace the glass cover ...

Page 14: ...onnecting piece Now loosen the fastening screws and take the cooker hood off the wall Once the cooker hood has been dismounted loosen the motor screws and remove the motor 4 2 3 Electronics unit In order to remove the electronics unit push the lower chimney upwards and secure it so that it cannot fall down Remove the two group sockets and the two screws Then pull out the electronics unit towards t...

Page 15: ... 0 GE and KDEM 9700 0 GE it is not possible to replace the canopy itself Only the bottom part as a whole unit can be replaced It is only possible to replace the glass canopy in the case of lines KD 9800 0 GE KDEM 9800 0 GE and KDUM 9800 0 GE See 4 1 4 to replace the glass canopy 4 2 5 Halogen lighting See 4 1 5 ...

Page 16: ... grease filter has been removed 6 Grease filter In order to remove the grease filter pull it downwards The grease filter is only held in place by means of magnetic strips Once the grease filter has been removed the safety chain must be removed Please note that on replacing the grease filter it is essential that the safety chain be installed If the grease filter is not secured with the safety chain...

Page 17: ...button will light up orange Press the activated button lights up orange once again to switch off the fan The intensive power setting is generally only used for a short period For this reason the cooker hood will switch back to power level 3 after 10 minutes When the intensive power setting is activated the Int button will light up orange 8 Lighting The lighting can be used on its own too without t...

Page 18: ...B A values are measured Halogen lighting number and output 2x 20 W Air extraction rate free blowing according to catalogue Min 355 m h Max 585 m h Intensive 750 m h Electrical connection 215 W Voltage 230 V Minimum clearance above electric hobs 650 mm Minimum clearance above gas hobs 750 mm Exhaust air connection diameter 150 mm KD 9800 0 IKD 10800 0 Min setting Max setting Int setting 44 dB A 59 ...

Page 19: ...H5 60 69 01 19 For internal use only 9 2 Wiring plans ...

Page 20: ...20 H5 60 69 01 For internal use only ...

Page 21: ...se OK Ö Replace the control unit Motor connection OK Ö Replace the magnetic core transformer Motor too loud Out of balance Ö Replace the motor Exhaust air path too narrow Ö Check the diameter and if necessary enlarge Aluminium flexible pipe Ö 4 db A louder Motor only runs at one speed Ö Check the keys Motor connection OK Ö Change the connections Capacitor defect Ö Replace the control unit Operatin...

Page 22: ...53 Min standard level 65 318 40 KD 9700 0GE High power setting 166 660 60 Max standard level 113 477 53 Min standard level 40 198 40 KDUM 9700 0GE High power setting 144 490 61 Max standard level 73 350 56 Min standard level 39 159 42 KDEM 9700 0GE EMA High power setting 200 677 60 Max standard level 170 572 56 Min standard level 72 280 41 KDEM 9700 0GE EMI High power setting 215 687 58 Max standa...

Page 23: ...andard level 36 190 44 KDUM 9800 0GE High power setting 106 400 61 Max standard level 91 318 59 Min standard level 38 159 46 KDEM 9800 0GE EMA High power setting 175 668 66 Max standard level 140 566 61 Min standard level 53 267 44 KDEM 9800 0GE EMI High power setting 195 680 62 Max standard level 150 585 59 Min standard level 65 280 43 Model Power consumption in watts Volume flow in m h Sound int...

Reviews: