7
Vent Configurations
10’
15’
20’
25’
30’
35’
40’
4’6”
5’0”
5’6”
6’0”
6’6”
7’0”
7’6”
8’0”
9’0”
10’0”
8’6”
9’6”
3” Liners
3” min. Bend
Radius
Ver
tic
al
Ven
t H
eigh
t
Allowable Horizontal Offset
10’
min.
- 40‘ max.
559CLT
Co-Linear Terminal
See
Chart
559CLT
Termination
3” Inlet & Exhaust
Collars (exhaust collar
is slighthly longer)
10”
10”
Allowable Vent Configurations
The RF24 is certified for use with approved 3” diameter
flexible venting installed into an approved existing solid
fuel burning masonry or factory built chimney system.
The venting system must terminate vertically at the
roof using an approved termination cap. Both inlet and
exhaust liners must be run continuously from appliance
to roof termination.
Where possible, avoid joints in flex pipe. If joints
are required, use only connectors approved by the
manufacturer of the flex pipe. Field fabricated joints are
not allowed.
Any generic 3” diameter flexible venting
approved
for venting gas appliances
is acceptable. See list of
the approved venting components on page 22 of this
manual.
WARNING
Failure to position the parts in
accordance with these diagrams or
failure to use only parts specifically
approved with this appliance
may result in property damage or
personal injury.