15. CLEANING 

All cleaning should be carried out when the heater is cold.  Normally, 

the heater should only need dusting.  Any stains on the glass can be 

removed with a non abrasive cleaner. 

Abrasive cleaners should never be used on the glass.

 

15.1 Cleaning the inside of the window: 

Open the case door fully.  Remove the window unit by detaching the 

knurled screws at sides near the top.  Lift the window unit assembly up 

to clear the locations at the bottom - see fig 7. In installation section of 

this manual. 

Be careful not to disturb the logs when removing the window.  If they 

are disturbed, refit them as described in the log installation section of 

this manual. 

Clean the window carefully by wiping with a soft cloth using a 

suitable non abrasive cleaner in accordance with the makers 

instructions.  Replace the window unit.  Locate its bottom edge in the 

support channels at the firebox sides.  Refit the two knurled screws and 

tighten.  Replace the window surround. 

 

16 PERIODIC CHECKS 

The venting system should be examined by a qualified agency 

regularly.  We suggest annually.  The flow of combustion and 

ventilation air must not be obstructed.  A periodic visual check of the 

pilot and burner flames should be made (see figs. 26 & 27) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17. CALLING FOR SERVICING 

For owner 

If you require any attention to your appliance, contact your supplier 

quoting the model number.  It is helpful if the appliance serial number 

is also quoted.  This will be found near the back of the case at the 

bottom right side. 

The servicing information on the following pages is for use 

only for a qualified service engineer.

 

        

 

 Fig. 26 Burner flames 

            

 

 Fig. 27 Pilot flame 

Содержание President 520AN

Страница 1: ...TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the...

Страница 2: ...og installation 9 Operation check 10 System pressure check 10 Venting check 10 Aeration adjustment 11 Completion of assembly 11 Final checks 13 Operating procedure 14 Lighting if igniter fails 14 Safe...

Страница 3: ...in the vicinity of the appliance after installation e g additional mantle etc make sure that the changes conform to the installation requirements in this manual Never attempt to burn paper or any othe...

Страница 4: ...for connection to the appliance inlet pipe located at the center back Rates Btu h Natural Gas Altitude Ft Max Min Input 0 2000 20 000 7 700 2000 4500 17 800 7 000 Output 0 2000 15 000 5 300 2000 4500...

Страница 5: ...red for use with a new zero clearance type installation It allows the heater to be installed with type B metal vent concealed behind a wall or partition and or in a chase Full installation and operati...

Страница 6: ...HEAVY The cast iron outer case supplied with President is a high quality casting weighing around 120lbs in total therefore it is supplied as individual components that are easily assembled together to...

Страница 7: ...emove the window unit assembly by detaching the knurled screws at the sides near the top Lift the window unit up to clear locations at the bottom and place carefully aside see fig 7 Carefully remove t...

Страница 8: ...Note In USA copper tubing must be internally tinned for protection against sulfur compounds Unions in gas lines should be of ground joint type The gas supply line must be sized and installed to provi...

Страница 9: ...ear and front burner tubes fig 12 Center the log so that the gap to the firebox walls is the same at each side 8 3 Place the cross log in position see fig 13 The front of this log is indicated by the...

Страница 10: ...Natural Gas only Max Min Supply upstream of heater regulator 10 5 5 0 Manifold Downstream of heater regulator at high setting 3 5 3 1 The burner manifold pressure is controlled by a built in non adju...

Страница 11: ...16 Take the cast iron Arched Lintel component and observe the fixing attachments on the rear and towards the inside top of the Side Panels Figure 17 Offer up the arched lintel component to the side pa...

Страница 12: ...the gas control valve and the control knob can vary If the shaft is too long it could prevent the cast iron knob access door from closing properly If the shaft is too short it could prevent the pilot...

Страница 13: ...rn off It must be explained that the gas control access panel must be kept open while the heater is in operation Advise that the fire can be lit with a long match or taper if necessary Advise that the...

Страница 14: ...lot cross lighting burner on Front burner on low Pilot cross lighting burner on Front burner on low Rear burner on high Pilot cross lighting burner on Front burner on high Rear burner on high 14 1 Lig...

Страница 15: ...ne Follow the gas supplier s instructions l l If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob wi...

Страница 16: ...n release The knob should pop back up Pilot should remain lit If it goes out repeat steps 2 through 6 If pilot does not light at all during a few attempts try lighting with a long match as described b...

Страница 17: ...oth using a suitable non abrasive cleaner in accordance with the makers instructions Replace the window unit Locate its bottom edge in the support channels at the firebox sides Refit the two knurled s...

Страница 18: ...ing make sure that the burner tube is properly located over the injector carrier at the right side 18 3 TO REMOVE THE ELECTRODE 1 Disassemble the outer case by reversing the procedures outline earlier...

Страница 19: ...tension rod valve spindle connector to the replacement valve 9 Refit in reverse order Test for leaks 18 8 TO REMOVE THE IGNITION SPARK GENERATOR 1 Remove the control valve and spark generator as 18 7...

Страница 20: ...20 Manufactured by HEATING BIRMINGHAM ENGLAND Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd 1996 2000...

Отзывы: