7 of 19
5.
SUPPLY GAS
Model 922ECN is for use only with natural gas. Model 922ECP is for use only with propane gas. The supply pressure must
be between the limits shown in section 3 of this manual.
The supply connection is
3
/
8
”NPT male thread. The supply pipe connection is to a flexible connector at the left hand side of
the appliance.
6.
PACK CONTENTS
This appliance requires more than one pack to complete the installation. The firebox unit is packaged separate from the front
trim. There is a choice of front trims to fit this unit (see section 3 of this manual). A 975 ZCK Zero Clearance Kit is
required when installing this appliance into any application other than as an insert into an approved solid fuel burning
fireplace.
922 - Firebox Unit
contains:
1 Burner & box Unit
1 Ceramic Wall Pack
1 Coal support
1 Coal pack
2 Wall
plugs
3 Screws
1 Flue spigot assembly
1
Remote control unit
(including the following)
1 Receiver
unit
1
Remote control hand unit
4 1.5V
AA
Batteries
1
9V Battery
One of the Optional front trims below must be used with this appliance ( see section 3 for diagrams)
923 - “Adorn” Cast Front
: (comes complete with wire guard )
539 “Windsor Arch
” cast front with back plate ( requires 540WDK wire guard when used with 922 firebox )
549 “ Windsor Arch “
cast front without back plate. ( requires 540 WDK wire guard when used with 922 firebox)
Note - The 540 WDK consists of a wire guard and mounting hardware as the Windsor Arch is not supplied with a wire
guard. Both the 539 and 549 Windsor Arch fronts are packaged with some redundant mounting hardware as they also fit other
models of fireboxes.
Take care when removing the contents from the packaging to prevent damage. Check that all the contents are in the packs and
are undamaged. Take special care in handling the ceramic walls and the coals.