21
X
Y
Dimensions
Cavity
Check that masonry step does not interfere with install dimensions
or vent pipe.
If mantel is combustible, see section
Clearances
for allowable
clearances.
Minimum width of
fi
replace opening at front: 20-1/2” (521 mm)
X = 9”–11-1/2” (229–292 mm)—varies with front trim options
Y = 25-1/2” (648 mm)
Note:
Using 546 Ledgeview front requires additional
1-1/2” (38 mm) cavity height.
25-1/4”
19-1/4”
2 x 3” dia.
colinear
vent
530 insert engine with
standard co-linear vent
Ensure base of heater is flush*
with finished hearth height,
otherwise front will not fit.
*
Note:
If installing
546 Ledgeview front,
4-sided frame drops 1-1/2”
below heater bottom.
25-1/4”
19-1/4”
See Front trims installation
manuals for dimensions
4-3/4”x 3” dia.
co-axial adaptor
530 insert engine with optional
530CVA co-axial vent adapter
20”
9” - 11-1/2”
depending on
front trim - see front
installation manual
QUALIFIED
INSTALLER