Front & Top Installation
Front
Installation
Hook the cast front to the side brackets located between the engine and the cast sides.
Cast front
Hook
Details
Engine
Side bracket
Air Shutter
Air Shutter in
Open
Position
Air Shutter in
Closed
Position
Air Shutter
Retainer
Air Shutter
Operation
Check
Aeration
Settings
Turn the fi replace fl ame up and down using the remote control to confi rm that the full range
of inputs is achieved—see the remote control operation instructions on pages 27–29.
Light the fi re and allow the unit to warm up for 10–15 minutes to evaluate the fl ame
picture. The burner is equipped with an adjustable shutter to control primary aeration. See
the fi gures below. The shutter is factory-set to an aeration gap which will give optimum
performance for the vast majority of installations. In a few unusual installations, the fl ame
picture may be improved by adjusting the aeration. The need for adjustment should be
determined only by operating the appliance with the ceramic logs and window installed.
Increasing aeration
will cause the fl ames to appear more transparent and blue making
the ceramic logs glow more.
Decreasing aeration
will cause the fl ames to appear more yellow or orange making the
ceramic logs glow less.
Too little aeration may result in black carbon forming and dropping into the fi rebox.