Owner’s Information
5. Apply
fi
rm hand pressure around the window frame
to ensure the window is sealed tight against the
fi
rebox.
6.
If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
7.
Replace the front or trim with the barrier screen
attached.
Hot Glass Plate
Correct Flame
Picture—Rocks
Correct Flame
Picture—
Driftwood
Thermocouple
probe must be
in flame
Correct Flame
Picture—Logs
Pilot Flame can be seen on the
left side of the fuel bed
Pilot
fl
ame
Thermocouple
probe must be
in
fl
ame
WARNING
FOR SAFETY PURPOSE, ensure the barrier
screen is re-installed on the
fi
replace front after
maintenance.
!
WARNING
Failure to install the window correctly can
leak carbon monoxide, affect the performance
of the
fi
replace, damage components, cause
overheating resulting in dangerous conditions.
Damage caused by incorrect window installa-
tion is not covered by the Valor warranty.
!
DANGER
The window unit must be correctly installed,
fastened and sealed after servicing or serious
bodily injury and/or damage to the appliance
may result.
To ensure a safe operation:
•
Double-check that the bottom of the window
frame is correctly installed in the bottom
support railing/tabs;
•
Verify that the bolts are hooked properly to
the window tabs then;
•
Pull out the top of the window and release it
to insure the springs return it;
•
Ensure the window is sealed before operation.
!
Checking pilot and burner
fl
ames
A periodic check of the pilot and burner
fl
ames should
be made. Check after the
fi
re has been on for at least
30 minutes. The pilot
fl
ame must cover the tip of the
thermocouple probe. The main burner
fl
ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Rock fuel bed
A black discoloration may form over time at the front
bottom of the 6-rock original fuel bed; this deposit
can be burned off by running the
fi
replace on a low
to medium setting
fi
re for 30 to 45 minutes. This
discoloration is unavoidable and will re-form again.
7
OWNER’S
INFORMATION