background image

Code

Description

Part 

Number

1

Exhaust Slide Assembly

4001133

2

Exhaust Slide Gasket

4001662

3

Fan Closure Plate

4001136

4

Port Cover

4001820

5

Log Support

4004353

6

Side Bricks Anchors (2)

4001283

7

Top Mounting Bracket

4000136AZ

8

Side Mounting Brackets (2)

4000135AZ

9

Window Assembly

4001378

10

Burner Assembly NG

4001375S

Burner Assembly LPG

4001376S

11

Burner Rail NG

4001665

Burner Rail LPG

4001666

12

Injector Elbow (Main Burner) NG

4000738

Injector Elbow (Main Burner) LPG

9730007

13

Air Shutter Cover NG

4002346

13a

Air Shutter Slider NG

4002345

14

Flashback Shield LPG

3000371

14a

Air Shutter Slider LPG

320B293

15

Burner Baf

fl

 e

4001784

16

Burner Mounts (2)

4001678

17

Pilot Shield

4000144

18

Pilot Assembly NG

4000062S

Pilot Assembly LPG

4000063S

19

Pilot Bracket

720A542

20

Pilot Injector NG—No 35

4002511

Pilot Injector LPG—No 27

720A195

21

Hooked Olive for Pilot Injector

720A196

22

Olive Nut for Pilot Pipe

420K385

23

Electrode

720A543

24

Electrode Retaining Nut

720A200

25

Thermocouple

4000061

26

Pilot Gasket A

4000139

27

Pilot Mount

4000138

28

Pilot Gasket B

4000140

29

Burner Tray

4001676

30

Pipe—Valve to Main Burner (incl. 
olive & nuts)

4000065

31

Burner Plate Access Panel

4001680

32

Module Gasket—Rear

4000175

33

Module Gasket—Right

4000174

34

Module Gasket—Front

4000173

Spare Parts

Code

Description

Part 

Number

35

Module Gasket—Left

4000181

36

Olive Nut for Pilot Pipe

220K913

37

Pipe—Valve to Pilot

4001838

38

Thermal Switch Retainer

4001519

39

Valve Mounting Bracket

4000141

40

Switch Bracket

4001070

42

Thermocurrent Interruptor

4001037

44

Hot Glass Warning Plate

4003093

45a

GV60 Valve Assembly NG

4003097

45b

GV60 Valve Assembly LPG

4003110

47

Switch with Cable

4001036

48

Cable Interruptor

4001035

49

Ignition Cable 500 mm

4001039

49a

Ignition Cable Sleeve

4002244

50

Receiver G6R-R3AM-ZV (CP)

4001911

51

Handset G6R H3T5-ZV (BJ)

4001910

52

Wiring Harness

4001187

53

Handset Wall Holder

9000008

54

Rock Set Complete 

739RSK

55

Rock No. 1 

4001821

56

Rock No. 2 

4001822

57

Rock No. 3 

4001823

58

Rock No. 4 

4001824

59

Rock No. 5 

4001825

60

Rock No. 6

4001826

61

Rock Base 

4001792

62

LH Twig 

4001827

63

RH Twig 

4001828

64

Glass Panel 

4001836

65

Front Support—Platform 

4001835BY

66

Ceramic Platform

4001832

67

Rock Support

4001768

68

Liner Set Complete

Fluted Black

739FBL

Valor Red Brick

739VRL

Re

fl

 ective Glass

739RGL

69

Rear Panel

Fluted Black

4001814

Valor Red Brick

4001811

Re

fl

 ective Glass

4005017

41

OWNER’S 
INFORMATION

Содержание LEGEND G3 739JN

Страница 1: ...ande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance is a dom...

Страница 2: ...Window 35 Synchronize Remote Control 36 Check Operation 36 Adjust Aeration if necessary 36 Install Front Trim and Barrier Screen 37 Install Handset Wall Holder 37 Wiring Diagram 38 Approved Venting Co...

Страница 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Страница 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Страница 5: ...r fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Phone Number _________...

Страница 6: ...AN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighting If broken the glass pane may only be r...

Страница 7: ...covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe...

Страница 8: ...ard The Lighting Operation and Rating information is located on a card under the burner To access the card remove the fret or access panel grab the card and take it out to read it There is important i...

Страница 9: ...s off when the handle is perpendicular with the pipe ON parallel to pipe OFF perpendicular to pipe How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following m...

Страница 10: ...lame height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 36 of this manual Set...

Страница 11: ...hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode Ma...

Страница 12: ...gramming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Temp...

Страница 13: ...ashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minutes SETTING P1 ON TIME SETTI...

Страница 14: ...ge in flame height for a period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appliance will continue to work n...

Страница 15: ...ew Front 4003313 765 Contemporary Surround 4003426 772MBF2 Matte Black Front 4004666 Optional Accessories Outer Surrounds Trims Frets See your dealer for your choice of Outer Surrounds Trims Frets Con...

Страница 16: ...smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH ON OFF switch 1 in...

Страница 17: ...Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370...

Страница 18: ...Barrier Screen required sold separately Fret optional sold separately 2 x 3 approved flex chimney liners running full length WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may...

Страница 19: ...Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowab...

Страница 20: ...Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non...

Страница 21: ...rmination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to c...

Страница 22: ...ance 3 Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing fireplace 7 Install and test blower if used 8 Fit appl...

Страница 23: ...le of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimension...

Страница 24: ...de in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the fireb...

Страница 25: ...the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screw...

Страница 26: ...t pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping...

Страница 27: ...2 Install the rock support supplied with the ceramic rocks set re using the screws from 1 4 screws Install Liner Panels The following guidelines apply for all liners except the 739RGL Reflective Glas...

Страница 28: ...panel against the firebox side The panel should be parallel to the edge of the burner plate Rotate the anchor back down to hold the panel 5 Tighten the side brick anchors on each side of the firebox...

Страница 29: ...of the sheet metal support Note The rear log will appear slightly angled backward on the left side compared to the burner The space between the log and the burner is purposefully wider on the left th...

Страница 30: ...to hide the sheet metal work Do NOT put any coal into the pilot area Notch in rear log Pin in front right log 4 Place the front right log on the burner and slide it to the left against the front left...

Страница 31: ...erformance of the appliance 1 Install the Front Support Platform in the firebox carefully sliding it down between the burner and the front bottom edge for the firebox while avoiding scraping the side...

Страница 32: ...g fire for 30 to 45 minutes This discoloration is unavoidable and will re form again Installation All Rocks installed Glass panel installed 6 Place the left twig across the second and third rocks from...

Страница 33: ...er performance of the appliance Platform Place the platform into the firebox on top of the burner Logs 1 Identify the base log and place it in the cavity of the ceramic platform The protruding parts o...

Страница 34: ...side cross log which has one pin at one end Insert the pin in the hole at the front left of the platform and rests the top part of the log into the notch of the rear log as indicated Pebbles Six pebbl...

Страница 35: ...tly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covere...

Страница 36: ...fireplace flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 10 14 Adjust Aeration if necessary Lig...

Страница 37: ...h plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between 3 and...

Страница 38: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram QUALIFIED INSTALLER 38...

Страница 39: ...o axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and...

Страница 40: ...mage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Ch...

Страница 41: ...o Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gasket Right 4000174 34 Module Gasket Front 4000173 Spare Parts Code Description Part...

Страница 42: ...4 LH Top Log 4003788 75 RH Top Log 4003789 76 RH Center Log 4003790 77 LH Front Log 4003792 78 RH Front Log 4003793 79 Loose Coals 4001843 80 Driftwood Kit 739DWK 81 Rear Log 4005615 82 Base Log 40056...

Страница 43: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 45a 45b 14a NG LPG 13a 47 48 49 50 51 52 53 49a 72 73 74 75 76 77 78 79 44 55 56 57 58 59 60 61 54 62 63 70 7...

Страница 44: ......

Страница 45: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Страница 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...