5
2.4
Orifice data
For verification only. Do not attempt to drill or
otherwise modify appliance input.
Model
Orifice
Type
No.of
Holes
Diameter
(ins.)
936 XN
Pilot
Front
Rear
Amal 40
Cat.18-340
Cat.18-380
1
7
7
0.022
0.025
0.027
936 XP
Pilot
Front
Rear
Cat.960-10
Cat.960-110
Cat.960-130
1
1
1
0.01
0.035
0.038
3. LOCATION IN THE ROOM
Combustible materials inside the room must not be closer
than the dimensions shown in figure 2.
The floor construction should allow the stove to be screwed
to the floor. If the stove is to be installed directly on any
combustible material other than wood flooring, it must be
installed on a metal or wood panel extending the full width
and depth of the appliance.
4. VENT LOCATION
4.1
The vent terminal must be located on an outside
wall.
4.2
The vent unit is suitable for wall thicknesses
between 3” and 24½”. If a vent extension is used
horizontally, this can be inserted in the wall allowing
for wall thicknesses up to 60¾”. See figure 1 for
limitations on use of horizontal extension.
4.3
The vent clearance hole required in the wall is 8
3
/
8
”
diameter.
4.4
The stove is supplied with a vent unit including a
90º elbow. This requires the center of th e vent hole
to be 47
5
/
8
” above bottom of the appliance if installed
with a pedestal base or 46” above the bottom of the
appliance if installed with legs.
This height must
not be reduced by cutting the vertical portion of
the elbow duct.
4.5
The 90º elbow can be rotated to allow the horizontal
run of the duct to be at any angle relative to the
appliance.
4.6
Do not attempt to use any vent material other than
that supplied with this appliance or kit #905VEK.
4.7
This direct vent appliance is designed to operate
when an undisturbed air flow hits the outside vent
terminal from any direction. The minimum
clearances from this terminal which must be
maintained are shown in figure 3. Any reduction in
these clearances could result in a disruption of the
air flow or a safety hazard. Local codes or
regulations may require greater clearances.
4.8
The terminal, when installed with the vent shield
tube and wall plates, is suitable for mounting on
wood or vinyl siding without requiring additional
shielding. The vent shield tube supplied is suitable
for wall thicknesses up to 24½”. A custom made
shield should be made for thicker walls.
4.9
The slots in the vent terminal must not be recessed
into a wall or siding.
4.10
The vent terminal should be positioned where it will
not be covered by any snowdrifts.
4.11
Warning:
If the outside vent terminal is located
where it will be accessible to any person, a guard
must be fitted over the terminal to prevent damage
and to prevent it being touched.
The vent terminal becomes very hot when the
appliance is in use and can cause burns. A special
guard designed for this appliance is available from
your supplier - Ask for Valor part #235 (See figure 4).