Valor Legend 736XN Скачать руководство пользователя страница 9

9

7.

REFIT THE WINDOW

1.

Hook the top of the window frame over the firebox
top front edge.

2.

Secure the window unit in place by refitting two
knurled screws at the bottom corners of the frame.

8.

CHECK OPERATION OF CONTROLS

Check ignition, valve control and thermostat settings as
described in the lighting instructions section of this manual.

9.

CHECK SYSTEM PRESSURE

The appliance is preset to give the correct heat input with the
gas for which it is designed.
For input adjustment, the gas supply pressure to the appliance
must be between the figures shown below.

SUPPLY PRESSURES

Model 736XN – Natural Gas

Maximum

10.5”w.c.

Minimum

5.0”w.c.

Model 736XP - Propane

Maximum

14.0”w.c.

Minimum

11.0”w.c.

The burner manifold pressure is controlled by a built-in non-
adjustable regulator. The manifold pressure must be between
the figures below.

MANIFOLD PRESSURES

Model 736XN – Natural Gas

Maximum

3.9”w.c.

Minimum

3.5”w.c.

Model 736XP - Propane

Maximum

9.4”w.c.

Minimum

9.0”w.c.

The manifold pressure should be checked at the pressure test
point which is located on the thermostat unit (see figure 16).
The pressure check should be made with the appliance
burning, the valve control set at “MAX” and the thermostat
control turned to “FULL”.

The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of

1

/

2

psig (3.5kPa). The appliance must be isolated from the gas

supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 

1

/

2

psig (3.5kPa).

10.

CHECK VENTING EFFICIENCY

A check for correct venting of combustion products must
be made before the installed appliance is left with the
customer. The test can be made before refitting the inner
front unit but the logs and window unit must be in
position.

Check as follows;

1.

Ignite the pilot and set the control knob to “MAX”
and the thermostat wheel to “FULL”.

2.

Leave the appliance on for 15 minutes then light a
smoke match and insert it inside the left side of the
top opening. Insert the match approximately 1

1

/

2

into the opening. See figure 23.
The installation is satisfactory if smoke is drawn into
the appliance.

3.

If the smoke is not drawn into the appliance, inspect
the sealing at the vent connection unit.

4.

If the sealing is satisfactory but the smoke is still not
drawn into the appliance, turn the unit off and check
the vent system for the cause of lack of draft. If
necessary, seek expert advice.

DO NOT LET THE APPLIANCE BE OPERATED
WITH INCORRECT VENTING

Figure 23. Venting Check

Содержание Legend 736XN

Страница 1: ...Massachusetts The gas piping and the final gas connection must be performed by a licensed plumber or gas fitter in the State of Massachusetts FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS T Open window...

Страница 2: ...pors and liquids Never attempt to burn paper or any other material in the appliance Keep the area in front of the bottom grill clear to prevent obstruction of air flow to the appliance for combustion...

Страница 3: ...677FSK vi 678FSK 21 2 Black Contoured Trim Covers 231 2 high x 361 2 wide vii 679FSK 21 2 Etched Champagne Contoured Trim Covers 231 2 high x 361 2 wide viii 2945 Brass Closure Plate Extends trim to...

Страница 4: ...y 4 per 1000ft altitude However these appliances have been specifically field tested for high altitude performance Therefore deration of Natural Gas appliances is not necessary or recommended for inst...

Страница 5: ...k that all the contents are in the pack and are undamaged 2 INSTALLING IN AN EXISTING FIREPLACE 2 1 PRE INSTALLATION PREPARATION 2 1 1 Closing Large Fireplace Openings This appliance is suitable for f...

Страница 6: ...gure 3 The maximum horizontal vent pipe length is 8ft and the minimum vertical vent pipe height is 8ft For full details please contact your dealer Prepare the appliance and install in position in acco...

Страница 7: ...the lower shaft back and park it in the slot opening in the right side of the appliance case figure 15d 4 2 GENERAL SUPPLY LINE REQUIREMENTS Openings for the gas supply line are provided at the back a...

Страница 8: ...at control wheel is turned 5 REFIT THE FRONT FRAME Place the front frame back in position and attach it to the appliance case with the four screws previously removed 6 FIT THE FUEL BED 1 Place the cer...

Страница 9: ...The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5kPa The appli...

Страница 10: ...necessary serviced annually 14 OPERATING PROCEDURE For your safety this appliance is fitted with a flame supervision device which will shut off the gas supply if for any reason the pilot flames go out...