The Oxysafe flame sensing and flue blockage safety system.
For your safety, this appliance is fitted with a flue blockage safety device which will
shut down the appliance in the event of abnormal flue conditions.
This device is NOT
a substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe which senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is held in at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off when
hot, always
wait at least three minutes before attempting to relight.
To light the fire.
The slide control is shown in figure 4.
1.
Slide the control button to the bottom (ignition) position
marked
. In this position, the electronic ignition system
should cause a series of sparks that should light the pilot.
Within four seconds of the pilot igniting, the main burner
should light at its minimum setting.
If no sparks are produced to light the pilot, the battery may
need replacing. Details of battery replacement are given in
the ‘Maintenance’ section of this guide.
Until you can obtain a replacement battery the fire can be lit
with a taper as described later in this guide.
2.
Keep the button at the ignition position for a further ten
seconds. This will prevent the flame-sensing device from shutting off the gas while its
probe warms up as explained above.
© GDC Group Ltd. 2012
PLEASE NOTE
When operating your fire for the first time, some vapours may be given off which
may cause a slight odour and could possibly set off any smoke alarms in the
immediate vicinity. These vapours are quite normal with new appliances. They are
totally harmless and will disappear after a few hours use.
PETRUS MODELS
After lighting the fire it is usual to have a light coating of condensation form on the
upper surface of the fascia and the area immediately above this. This should
disappear in approximately five minutes and is no cause for concern.
Figure 4. The control
Содержание Homeflame Dream
Страница 4: ...INSTALLER GUIDE Page 4 GDC Group Ltd 2012 INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 47 TO 63...
Страница 47: ...OWNER GUIDE Page 47 GDC Group Ltd 2012 OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 60 TO 63...
Страница 64: ...GDC Group Ltd 2012...
Страница 65: ...Page 65 GDC Group Ltd 2012...
Страница 66: ...Page 66 GDC Group Ltd 2012...