Valor Hamlet Multifuel Stove
17
SERVICING & MAINTENANCE
DOOR ADJUSTMENT
Once the appliance has been under fire for a period
of time the fire door may appear to have moved out
of alignment with relation to the door aperture. This
is quite normal and due to the settling of the casing.
The fire door can be re-aligned by the user as
follows:
•When the appliance is cold, open the fire door so
that it is at a right angle to the front face of the
stove.
•Lift the fire door up off the hinges.
•Check that the hinge screws are tight and secure.
•Gently tap the two hinge pins in a direction to
compensate for the misalignment, see fig. 17.
•Refit the door and check to ensure it now sits
square to the body and the central gap between each
door is even, if not repeat above steps.
Fig. 17. Adjusting The Door Hinges
FUEL RETAINER BARS
Fuel retainer bars are supplied with the stove. Slide
and lift the bar until it is clear of the guides at each
side, and remove through the fire door opening.
The bars are symmetrical and of even lengths
making incorrect fitting impossible.
Periodically check for any bowing or heat warpage
to the fuel retaining bars and replace as necessary.
Note: This operation should only be carried out
when the appliance is cold and unlit.