![Valor H5 1100MN Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/valor/h5-1100mn/h5-1100mn_installation-manual_3616650043.webp)
43
ONLY If You Are Installing HeatShift
Perform the following steps and see Appendix D -
HeatShift System on pages 83-101 for more details
regarding HeatShift planning and installation.
Remove Convection Ba
ffl
e
To be e
ff
ective, the HeatShift system requires that an
internal convection ba
ffl
e located above the
fi
rebox
inside the appliance case be removed to allow the hot
air
fl
ow to convect upwards into ducts installed on the
fi
replace.
Remove the convection ba
ffl
e from the appliance. It is
held in place by 3 screws located right behind the upper
edge of the
fi
replace opening. Recycle this panel as it is
no longer needed.
Appliance Preparation
Optional HeatShift
Install HeatShift Take-O
ff
Collars
1. Remove the four cover plates on top of the appli-
ance case (6 screws each).
2. Install the four take-o
ff
collars on the holes on top
of the appliance’s case (6 screws each).
WARNING
A l l F O U R ( 4 ) t a k e o f f s M U S T B E
C O N N E C T E D T O P L E N U M ( S ) .
WARNING
The H5 fireplace
requires the removal
of the internal convection baffle
for the
HeatShift system to function properly—
read instructions carefully!
Appliance top shown transparent for clarity
Remove convection ba
ffl
e—1100M
Conve
ction B
a
ffl
e