Valor H5 1100MN Скачать руководство пользователя страница 5

5

Barrier Screen and Safety

• A barrier designed to reduce the risk of burns from 

the hot viewing glass is provided with this appli-

ance and must be installed for the protection of 

children and other at-risk individuals.

• Any safety screen, guard, or barrier removed for 

servicing an appliance, must be replaced prior to 

operating the appliance. 

• If the barrier becomes damaged, the barrier must 

be replaced with the manufacturer's barrier for 

this appliance.

Initial and annual inspection 

• The appliance and venting system should be in-

spected before initial use and at least annually 

by a professional service person. 

• Installation and repair should be performed by 

a quali

fi

 ed service person. The appliance should 

be inspected before use and at least annually by a 

professional service person. More frequent clean-

ing might be required due to excessive lint from 

carpeting, bedding material, etc. It is imperative 

that control compartments, burners, and circulta-

ing air passageways of the appliance be kept clean.

• Do not use this appliance if any part has been 

under water. Immediately call a quali

fi

 ed service 

technician to inspect the appliance and to replace 

any part of the control system and any gas control 

that has been under water.

 Intended use 

• This appliance is designed and approved as a 

supplemental heater to be used while attended. 

The use of an alternate primary heat source is 

advisable.

• This unit is not for use with solid fuel.

Maintenance

• Keep the unit’s control compartment, burner, and 

circulating air passageways clean to enable ad-

equate combustion and ventilation air.

• Inspect the external vent cap on a regular basis to 

ensure that no debris, plants, trees, or shrubs are 

interfering with air 

fl

 ow. 

Venting

• This unit must be used with a vent system as 

described in the installation manual. No other vent 

system or components may be used.

• Never obstruct the 

fl

 ow of combustion and venti-

lation air. Keep the front of the appliance clear of 

all obstructions for optimal operation and ease of 

servicing.

• This unit must be vented directly outside and must 

never be attached to a chimney serving a separate 

solid fuel burning appliance. Each gas appliance 

must use a separate vent system. Common vent 

systems are prohibited.

Safety and your fireplace

Front outlet

WARNING

Optional HeatShift 

System:

Do not cover or 

place items in

front of outlet!

Top outlet

Sides outlets

Содержание H5 1100MN

Страница 1: ...r gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified i...

Страница 2: ...rohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used INS...

Страница 3: ...______________________ Options ________________________________________ ________________________________________________ ________________________________________________ Please ask your installer for...

Страница 4: ...h safe they may reach temperatures in excess of 200 F depending on elevation of the shelf Do not place anything on it Some materials or items although safe may dis color shrink warp crack or peel due...

Страница 5: ...alified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Intended use This appliance is designed and approved as...

Страница 6: ...n they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in th...

Страница 7: ...flames will be at their normal height Valor automatic gas shut o For your safety Valor fireplaces are fitted with a flame supervision device which will shut o the gas supply if for any reason the pil...

Страница 8: ...lled Your individual fireplace may appear differently depending on your installed options Barrier Screen Window Frame Window Frame Liner Panels Side Door Fireplace info card behind right door Fuel Bed...

Страница 9: ...r fireplace OFF including pilot Press and hold button on remote or ON OFF button on wall switch If the flames or pilot are on they will go out and you will hear the valve motor wind down You will hear...

Страница 10: ...fireplace will not turn on unexpectedly On gas valve turn dial from ON position to MAN position as shown Turning dial to MAN will ensures that main burner cannot come on The pilot will remain on if li...

Страница 11: ...he fireplace is hot Let the fireplace cool first before touching it Caution Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could...

Страница 12: ...cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning See Cleaning your fireplace on page 13 Inspect the operation of the flame safety sys tem Pilot or Flame re...

Страница 13: ...Window The window is held in place by 4 spring loaded latches on each side of the firebox 1 To remove the window locate the four latches around the window frame 2 For each of the four latches pull th...

Страница 14: ...If broken glass panes may only be replaced as a complete window unit as supplied by the manufac turer If the barrier screen becomes damaged it must only be replaced with the same model and version ba...

Страница 15: ...eplace Damage components Cause overheating resulting in dangerous conditions Damage caused by incorrect window installation is not covered by the Valor Warranty Reinstall and Check Window To reinstall...

Страница 16: ...on the fireplace front after maintenance Hot Glass Warning Plate 5 If the Hot Glass Warning plate has been removed from the front lower corner of the window reinstall it by sliding it between the glas...

Страница 17: ...l inspection Sooting Check your fireplace and outside terminal for any sooting Minor amounts of soot developing on logs is common but soot that builds up falls o and accumulates indicates the burner n...

Страница 18: ...critically low not the batteries in your remote control handset but the batteries in the battery holder beside the wall switch See page 11 for instructions on how to replace the batteries Why do I he...

Страница 19: ...vice technician Contact our dealer quoting the model and serial numbers if possible These numbers can be found on the fireplace information card attached to the fireplace see page 7 Why does my pilot...

Страница 20: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Страница 21: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the w...

Страница 22: ...if included Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco Mode F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Pres...

Страница 23: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 24: ...r only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light t...

Страница 25: ...WiFi the handset will display APP Manual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset t...

Страница 26: ...To con rm press ON ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes...

Страница 27: ...imum countdown time is 9 hours and 50 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit...

Страница 28: ...no pilot ame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery s...

Страница 29: ...ss and hold large flame button to gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can tur...

Страница 30: ...30 Notes...