Figure 46. Control
1 4 F U L L O P E R A T I N G C H E C K S
14.1
Check the Control Settings
The control position markings on the front surround are shown in figure 46.
Please note:
•
When first turned on from cold, the flames will appear predominantly blue.
•
When operating the fire for the first time, some vapours may be given off which could
set off smoke alarms in the vicinity. These vapours are quite normal with new appliances.
They are totally harmless and will disappear after a few hours use
.
1.
Make sure the slider button is at the off position (At topmost position marked “
O
” on
the front surround).
2.
Open the isolating valve on the inlet elbow.
3.
Slide the button to the bottom (ignition) position marked
✩
. Retain in this position to
ignite the pilot. The burner should ignite at its lowest setting within 4 seconds of the pilot
igniting. Keep at this position for a further 10 seconds to allow the pilot flame to
stabilise.
4.
Release the button. The button should automatically spring up to the low heat
position. If the flames go out at this stage
or when checking the rest of the setting
positions, try the full lighting sequence
again. If the flames fail after two attempts,
investigate the pilot unit.
5.
Gradually slide the button up to
increase the burner setting. The burner
should be at its maximum setting at the
high heat position shown in figure 46. You
should feel a check to the button
movement at this position.
6.
Slide the control button up past the high
heat position to the off (“
O
”) position at
the top of the slide slot. Both pilot and
main burner should go out. While cooling
the coals may make some crackling noises.
This is quite normal.