INSTALLER’S GUIDE
Page 20
in figure 13.
Secure the fireback
spacers using the screws removed
previously and the two supplied with
the fire.
8.
This appliance is supplied with
a flue restrictor for use where the flue
draught is excessive. The restrictor
must NOT be fitted where a precast
flue or a flue liner is used. For all
other installations the restrictor
should be fitted. There may however,
be certain exceptional circumstances
where fitting the restrictor causes
the fire to fail the spillage test. In
such cases the restrictor will have
to be removed. After removal
conduct the spillage check again.
The restrictor is packed loose
with the appliance and is fixed
with two screws. See figure 14.
9.
There is a length of self
adhesive foam seal supplied with
the fire. This will need to be fitted
to the outer rear edges of the side
and top flanges of the hotbox. Cut
a 485mm length of foam seal. Be
careful not to stretch the seal
when measuring. Remove the
protective backing from the foam
seal and fit this to the rear of the
top flange (See figure 15). Cut
two 580mm lengths. Fit these to
the rear outer edges of the side
flanges. Ensure that there is no
gap between the foam seals where they meet at the top flange (See figure 15).
Figure 15. Fitting the foam seal
Figure 14. Flue Restrictor