Valor AutoFire G4 Скачать руководство пользователя страница 6

6

 Specifications

Approval & Codes

This appliance is certi

fi

 ed to ANSI Z21.88/CSA 2.33 

American National Standard / CSA Standard for Vented 

Gas Fireplace Heaters for use in Canada and USA, and 

to CGA 2.17-91 High Altitude Standard in Canada. This 

appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing 

method for measuring annual 

fi

 replace e

  ciencies.

The installation must conform to local codes or, in 

the absence of local codes, with the National Fuel 

Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas 

and Propane Installation Code CAN/CGA-B149.1. Only 

quali

fi

 ed licensed or trained personnel should install 

this appliance.
This appliance must be electrically grounded in 

accordance with local codes, or, in the absence of local 

codes, with the National Electrical Code, ANSI/NFPA 70 

or the Canadian Electrical Code, CSA C22.1.

 Ratings

*High Altitude Installations

Input ratings are shown in BTU per hour and are 

certi

fi

 ed without deration for elevations up to 4,500 

feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, 

installations must be in accordance with the current 

ANSI Z223.1 and/or local codes having jurisdiction. 

Heating value of gas in some areas is reduced to 

compensate for elevation—consult your local gas utility 

to con

fi

 rm.

For installations at elevations above 4,500 feet (1,370 m) 

in Canada, please consult provincial and/or local 

authorities having jurisdiction.

Model 

785YN

785YP

Gas

Natural

Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

28,000

26,000

Input Minimum (Btu/h)

15,000

13,000

Manifold Pressure (in w.c.)

3.2”

9.5”

Minimum Supply Pressure (in w.c.)

5”

11”

Maximum Supply Pressure (in w.c.)

10”

14”

Main Burner Injector Marking

850

300

Pilot Injector Marking

51

30

Min. Rate By-Pass Screw

190

125

Supply Gas

Heater engine 785YN is used with natural gas.
Heater engine 785YP is used with propane gas.
The supply pressure must be between the limits shown 

in the Ratings section.
The supply connection is 1/2” NPT female and located 

on the left side of the control valve. The gas line entry 

point is on the the upper left hand side of the 

fi

 replace. 

See 

Gas Supply

 pages 17–19 for connection details.

Electrical

The 785 G4 is designed to run on battery power and 

does not require an electrical source to operate as a 

heater. However, if the appliance is 

fi

 tted with a fan, a 

grounded power source is required.

Conversion Kits

The 785 is supplied as natural gas or propane gas and 

is 

fi

 eld convertible between fuels. See instructions 

packaged with the conversion kits for further 

information.

Floor/Hearth

This appliance is approved for installation into existing 

solid-fuel burning 

fi

 replaces only. Combustible material 

such as plywood and so on may be used for leveling 

and shimming beneath the unit. This appliance does 

not require a hearth other than to support the weight 

of certain fronts.

X

X

Note:

 This appliance is designed and approved as 

a supplemental heater and provides the potential 

for most energy conservation when used while 

attended. The use of an alternate primary heat 

source is advisable.

Содержание AutoFire G4

Страница 1: ...r call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Hot glass will cause burns Do not touch glass until cooled Never allow...

Страница 2: ...h Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by...

Страница 3: ...paration 14 Unpack the Appliance 14 Remove Window 15 Install Fan Kit if used 15 Installation 16 Connect Venting 16 Gas Supply 17 Liner Panels 19 Remove and Re install Burner if necessary 19 Fuel Beds...

Страница 4: ...installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other combustibl...

Страница 5: ...st use a separate vent system Common vent systems are prohibited WARNING Do not operate this appliance with the glass front removed cracked or broken Replacement of the glass front should be performed...

Страница 6: ...del 785YN 785YP Gas Natural Propane Altitude Ft 0 4 500 feet Input Maximum Btu h 28 000 26 000 Input Minimum Btu h 15 000 13 000 Manifold Pressure in w c 3 2 9 5 Minimum Supply Pressure in w c 5 11 Ma...

Страница 7: ...ing 4 Sided Trims 4003371AZ 798FFB Black 798FFV Vintage iron 798FFZ Bronze 799ED Edgemont Door Kits 4004348AZ 799EDFZ Bronze 799EDFN Nickel Backing Plates choose one 799BPB 1 799BPB 2 799BPB 3 3 Sided...

Страница 8: ...ance by 2 13 16 72 mm Plan accordingly Dimensions 33 838 mm 24 610 mm 15 381 mm 15 381 mm 4 102 mm 3 76 mm 3 76 mm 3 76 mm 23 584 mm to top of firebox Gas line access Gas line approx 24 610 mm of flex...

Страница 9: ...aterials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C Clearances WARNING Some materials or items although safe may discolo...

Страница 10: ...side of the appliance liner box Floor Hearth Clearances Combustible shims supports may be used beneath the appliance to level or raise the appliance within the existing fireplace cavity Combustible fl...

Страница 11: ...eet Also check that you have A fuel bed packed separately Liner panels packed separately Venting accessories Electrical accessories if using a fan kit Any other ordered accessories 4 Carefully read th...

Страница 12: ...sting non combustible hearth Combustible hearth or floors within 16 of insert must be a minimum 4 102 mm below bottomr of insert Gas insert does not require a hearth WARNING Some materials or items al...

Страница 13: ...allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run...

Страница 14: ...ting Dampers Factory built zero clearance fireplaces will require the damper to be removed in order to install the vent liners These dampers are usually bolted into place Dampers in masonry fireplaces...

Страница 15: ...commend that where possible the fan be installed before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan 6 power cord Remove Window The windo...

Страница 16: ...ebox by sliding it towards the back of the firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose clamps inc...

Страница 17: ...upply of gas su cient to meet the maximum demand of the appliance without undue loss of pressure Sealant used must be resistant to the action of all gas constituents including LP gas Sealant should be...

Страница 18: ...er installation or servicing All leaks must be corrected immediately When testing for leaks Make sure that the appliance is turned o Open the manual shut o valve Test for leaks by applying a liquid de...

Страница 19: ...lternate Inlet Connection In cases where local codes do not permit the flex connector to be used inside the appliance case reconnect the flex connector outside of the appliance case A cut out is provi...

Страница 20: ...nifold bracket as indicated 2 Grab the burner and gently pull up the rear first while pushing back and unhooking the front tabs from their retaining lances Be careful not to hook the pilot hood as you...

Страница 21: ...Note There are two sets of holes for this log de pending which type of gas is uesd for the appliance Natural gas fire Place the log forward in the fire box Propane gas fire Place the log rearward in t...

Страница 22: ...add some shale on cavity outer edge Note Ensure the area within the pilot shield is clear of shale pieces Pebbles Place the pebbles on the platform as shown below IMPORTANT Approved for use only with...

Страница 23: ...e glass platform on top of the retainers Installation Fuel Beds 4 Carefully spread the glass by hand on top of the burner within the platform opening 5 Install the square glass panel on top of the pil...

Страница 24: ...e as indicated below Window frame Bottom railing Hot Glass Plate WARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the a...

Страница 25: ...hold the receiver s RESET button until you hear one short and one long beep Release the reset button after the second beep 5 Within the subsequent 20 seconds press the small flame button on the remote...

Страница 26: ...isible at the left hand end of the burner Increasing aeration open will cause the flames to appear more transparent and blue showing more ceramic e ects glow Decreasing aeration close will cause the f...

Страница 27: ...ront Trim and Barrier Screen Install the front or trim chosen by the customer for their fireplace Install as well the barrier screen which is provided with the front or trim Show the customer how to a...

Страница 28: ...that the holder can be installed at the base of a light switch plate IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temp...

Страница 29: ...LOT MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button Optional Wall Switch Kit Connector Thermocouple 8 Wire Cable bundled ON OFF Switch Optional 795CFK...

Страница 30: ...T33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and others 2280 Series AF3 35L TM ALK33 9...

Страница 31: ...I RX VPHOO JDV 6TOP Follow LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWep 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER 21 2 VZLWFK LQ 21 SRVLWLRQ 0 1 NQR...

Страница 32: ...arth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperature 6PDOO DPH EXWWRQ DPHV GRZQ DQG R VHWV PLQXWHV temper...

Страница 33: ...lot is lit room temperature is measured and compared to set temperature Flame height automatically adjust to reach Daytime Set Temperature Light Dimmer Mode Not available on this replace Fan Mode Turn...

Страница 34: ...ss SET to scroll to TEMP Hold SET button until TEMP ashes To set Night Time Temperature increases temperature decreases temperature Press or wait to complete setting Setting Program Timers You can pro...

Страница 35: ...ended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months and...

Страница 36: ...9 Pilot hood 2 flame 4001756 30 Extended nut 4001855 31 Electrode 4001856 32 Injector elbow 850 natural gas 9730010 Injector elbow 300 propane 9730035 Description Part Number 33 Injector nut 420K464 3...

Страница 37: ...t side panel a Ledgestone V3 4007998 b Reflective Glass 4004708 b Filler panel 4002776 c Ceramic fluted black 4002377 d Valor red brick 4002381 68 Right side panel a Ledgestone V3 4007999 b Reflective...

Страница 38: ...68 1 2 3 4 5 7 8 9 10 11 13 6 19 24 25 20 14 15 15 17 18 16 26 29 30 31 32 33 21 22 23 4 43 44 58 45 46 47 48 49 50 51 52 53 61 62 62 63 60 59 40 35 36 37 42 6 34 38 39 41 69 785XDGM 1101DWK 70 Appen...

Отзывы: