18
Installation
Gas Supply
WARNING
NEVER USE AN OPEN FLAME to check
for leaks. Correct any leak detected
immediately.
Manifold Test
Pressure
Valve Inlet
Pressure
Valve Assembly
Control
Valve
34” (864 mm)
fl
ex pipe
supplied with
appliance
Shut-o
ff
valve
supplied with
appliance
1/2” NPT
female
Manifold
Pressure
Adjustment
behind
Plastic Cap
Pressure Test Points
The minimum supply pressure is given in the section
Speci
fi
cations
on page 6 of this manual.
All piping and connections must be tested for leaks
after installation or servicing. All leaks must be
corrected immediately.
When testing for leaks:
• Make sure that the appliance is turned o
ff
.
• Open the manual shut-o
ff
valve.
• Test for leaks by applying a liquid detergent or soap
solution to all joints. Bubbles forming indicate a gas
leak.
The pressure test tapping locations are shown in the
fi
gure below. An internal regulator within the valve
controls the burner manifold pressure.
The correct pressure range is shown in the table in
section Speci
fi
cations of this manual on
Speci
fi
cations
on page 6.
The pressure check should be made with the burner
alight and at its highest setting—see
Appendix A -
Lighting Instructions Plate
on page 31 for full operating
details.