Figure 13
Maintaining Your Fire
Always disconnect the heater from the electricity supply by removing the 3 pin plug and allowing
the heater to cool before undertaking maintenance or replacing lamps.
Lamp Replacement
The lamps fitted to this heater are long life types, but due to the indeterminate life span
and ease of replacement are specifically excluded from the guarantee.
To replace a lamp.
All Models except Adorn and Icon
Remove the accessible loose coals. Unhook the front casting by lifting slightly to
disengage the unit from the keyhole slots in the trim and gently pull forward.
Replace with a
60W (maximum) clear
Edison screw
lamp. Do not use opaque or
coloured lamp bulbs.
Refit the front castings and relocate the coals.
Adorn and Icon Models
Remove the coals (Adorn). Lift out the coal support/fuel effect. It will also be
necessary to remove the effects drum to access the lamps. To remove, hold the drum
and firmly slide it to the right to disengage it from the motor spindle, withdraw it from
the heater See figure 13.
Replace with a
60W (maximum) clear
B22
Edison screw
lamp. Do not use opaque
or coloured lamp bulbs.
Refit the drum by sliding onto the motor spindle and pushing the other end into its
location socket – See figure 13. Check that the drum rotates correctly.
Refit the coal support/fuel effect and coals (Adorn).
Automatic Cut Out
A cut out is fitted to the heating element to prevent damage due to over heating. If it
operates due to an obstruction in the airflow, the heater must be turned off and allowed to cool for 15 minutes, obstruction
removed before restarting.
Care and Cleaning
The canopy trims and glass parts need only to be wiped clean with a dry soft cloth, do not use polishes or abrasive
materials.
Fault Finding
No or low light from the fuel effect:
Check the lamp dimmer is turned to high, if it is, then it is possibly a lamp failure.
Remove the lamp as detailed above and check it in a table lamp, that is known to work.
No heat or light:
Check the wall socket by plugging in a known working appliance. If functional check the 13A fuse in
the heater plug. If either fuse or socket is suspected, have them checked by an electrician.
Light but no heat:
The automatic cut out, may have operated, see above.
Disposal
At the end of the products serviceable life it should be disposed of thoughtfully and safely in accordance with local
authority regulations. The plug should be removed from the mains cable and the mains cable cut from the heater.