background image

Replace the minimum rate by-pass screw

1.  Locate and remove the by-pass screw from the valve 

and discard. The by-pass screw has a rubber O-ring 
and may need to be pulled out using pliers after 
unscrewing.

2.  Insert the replacement minimum rate by-pass screw 

and hand tighten using a screwdriver. Refer to the 
Specifi cations table on page 1 for proper by-pass 
screw. Note that the number is stamped on the barrel 
of the screw. 

Adjust the air shutter

The air shutter is located at the back of the ceramic fuel 
bed.
1.  Loosen the screw of the air shutter.
2.  Slide the shutter as indicated below according to the 

type of gas used.

3.  Re-tighten the screw.

3.  Replace with the appropriate pilot injector—see 

Specifi cations

 table on page 1. Screw in the new 

injector.

4.  Refi t the pilot head by pushing down on it. Ensure 

that it snaps into position.

Re-assemble the module 

1.  To re-install, is a reversal of the procedure.
2.  Position and locate module in the fi rebox. 

Be 

careful not to trap cables between fi rebox and 
module.

3.  Secure module to fi rebox with previously used 

screws.

4.  Reconnect gas inlet to valve tightening pipe 

connection. Open shut off  valve and inspect

5.  Test for leaks by applying a liquid detergent or soap 

solution to inlet connection joint. Bubbles forming 
indicate a gas leak.

Never use an open fl ame to check for leaks.
Correct any leak detected immediately. 

Re-install the burner and liners

1.  Holding the burner as indicated, gently lower the 

front fi rst and then the rear. 

Be careful not to hook 

the pilot hood as you locate the burner

2.  Secure the burner platform with the 2 screws fi xing 

the rear of the burner to the manifold bracket as 
indicated. 

3.  Re-install liner panels.

Air 

shutter 

screw

Propane Gas

Natural Gas

5/8” 

(16 mm)

5/8” 

(16 mm)

Minimum rate by-pass 
screw location

3

Содержание 785KNGK

Страница 1: ...sure Small flat blade screwdriver to release pressure tap on valve Needle nose pliers to remove by pass screw Hex Allen wrench 4 mm or 5 32 to remove pilot injector Manometer to set pressure regulator is integral with valve Specifications Use with with Valor Models 785K Heaters ONLY WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s inst...

Страница 2: ...pull the burner up 5 Locate shut off valve and isolate then remove 6 screws holding access panel in place 6 Using two wrenches disconnect inlet to valve control 7 Remove remaining screws holding module plate to side wall of firebox and two screws fastened to base 8 Withdraw module from firebox 9 Supporting injector elbow unlock and remove pipe assembly remove injector locknut from inside manifold hou...

Страница 3: ...down on it Ensure that it snaps into position Re assemble the module 1 To re install is a reversal of the procedure 2 Position and locate module in the firebox Be careful not to trap cables between firebox and module 3 Secure module to firebox with previously used screws 4 Reconnect gas inlet to valve tightening pipe connection Open shut off valve and inspect 5 Test for leaks by applying a liquid dete...

Страница 4: ...ressure Decreases pressure Manifold Pressure Test Tap Valve Inlet Pressure Loosen screw to check tighten afterwards Pressure Test Tappings 5 Turn off the appliance remove the manometer and tighten the test tapping screw Check for leaks 6 Complete the required details of label This appliance was converted on by position along with the label This control has been converted onto the inside face of the...

Страница 5: ... maximal Btu h 28 000 28 000 Apport minimal Btu h 17 500 13 000 Pression d admission en c e 3 2 10 5 Pression d alimentation minimum en c e 5 0 11 0 Pression d alimentation maximum en c e 10 0 14 0 Injecteur brûleur principal 850 300 Injecteur de veilleuse 51 30 Vis d indice minimum 220 125 AVERTISSEMENT Ce kit de conversion doit être installé par une agence de service qualifiée selon les directive...

Страница 6: ...rrêt isolez le raccord enlevez la 6 vis retenant la plaque d accès en place 2 Utilisez deux clés pour débrancher la conduite de gaz reliée à la soupape 3 Enlevez les autres vis retenant la plaque du brûleur au côté et à la base de la boîte de foyer 4 Sortez la plaque du foyer 5 En supportant l injecteur coude débranchez la conduite et enlevez l écrou de verrouillage de l injecteur de l intérieur d...

Страница 7: ...le nouvel injecteur et serrez le Réinstallez la plaque du brûleur 1 Procédez à l inverse pour réinstaller la plaque du brûleur 2 Placez la plaque du brûleur dans la boîte de foyer insérant la soupape en premier Faites attention de ne pas coincer les câbles et fils entre le fond de la boîte de foyer et la plaque du brûleur 3 Fixez la plaque du brûleur avec les 8 vis enlevées plus tôt 4 Rebranchez la...

Страница 8: ...sultez le guide d installation du foyer pour réinstal ler les bûches du foyer ou pour continuer l installation Apposez les étiquettes de conversion 1 Complétez les informations requises sur l étiquette Cet appareil a été converti le par 2 Apposez l étiquette d indices signalétiques et l étiquette de conversion au verso de la carte de directives d allumage roulée à la droite de la boîte 3 de foyer ...

Отзывы: