Side Shrouds Installation
Operation Check & Aeration Settings Adjustment
Operation Check
Turn the
replace
ame up and down using the
remote control to con
rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 10-15.
Aeration Settings
Light the
re and allow the unit to warm up for 10–15
minutes to evaluate the
ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the
gures below. The shutters are
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
In a few unusual installations, the
ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic logs and window installed.
Increasing aeration (open)
will cause the
ames
to appear more transparent and blue showing more
ceramic effects glow.
Decreasing aeration (close)
will cause the
ames to
appear more yellow or orange showing less ceramic
effects glow.
Too little aeration may result in black carbon
forming and dropping into the
fi
rebox.
Air Shutters
Open
Open
Close
Close
NG
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Open
Close
LPG
NG Air Shutter
Slider & Cover
The side shrouds are required to install the front on the
appliance. They are supplied with the engine.
Fit them to the appliance outer case as indicated
(2 screws/side).
Door hinge
points should
face inwards
36
QUALIFIED
INSTALLER
Содержание 780JN