3.19
Proprietary terminals must comply with BS 715 or BS 1289. Any terminal or
termination must be positioned in accordance with BS 5440 Part 1 to ensure that the
products of combustion can be safely dispersed into the outside atmosphere. Where the
appliance is connected to an unlined brick chimney it is generally unnecessary for the
chimney pot to be replaced or for a terminal to be fitted unless the flue has a diameter
smaller than 170mm.
3.20
The appliance is fitted with an A.S.D (Atmosphere sensing device). If the
appliance closes down after a period of operation for no apparent reason, the consumer
should be informed to stop using the appliance until the installation and appliance have
been thoroughly checked. The A.S.D will shut the appliance down if an unacceptable
amount of harmful products of combustion accumulate. Under no circumstances should
the A.S.D be altered or bypassed in any way. Only a genuine manufacturers replacement
part should be fitted. The individual A.S.D components are not replaceable.
3.21
A fireguard complying with BS 8423 should be fitted for the protection of young
children, the elderly, or the infirm.
4. PACK CONTENTS
The items required for this appliance are packed in two sections.
Section 1 - Fire unit contains:
1
Convection box and burner unit
1
Loose parts pack including: -
1
Nut and Olive for 8mm Inlet Pipe
1
Front base coal
1
Rear base coal
1
Pack of loose ceramics
2
Small ‘U’ seals for convection box side flanges
1
Strip of Floor Sealing Tape
1
Flue restrictor with 2 securing screws
6
Fibre Plugs
4
Woodscrews
2
Tension Cables
2
Cable Adjusters
4
Eyebolts
1
Installation template
1
Smoke match tube
Page 12
INSTALLER GUIDE