background image

Page 37

INSTALLER GUIDE

Содержание 719

Страница 1: ...he United Kingdom In the Republic of Ireland call 0044 08706 061 065 INSTALLER Please leave this guide with the owner Valor Heating Model 719 GC No 32 032 53 INSET LIVE FUEL EFFECT GAS FIRE INCORPORAT...

Страница 2: ...a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company All our gas fires must...

Страница 3: ...5 1 Check for Spillage 27 15 2 Flame Supervision Spillage Monitoring System 28 16 FINAL REVIEW 29 17 SERVICING PARTS REPLACEMENT 30 17 1 Checking the aeration setting of the burner 30 17 2 To Remove t...

Страница 4: ...btain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Do not...

Страница 5: ...icensed for the disposal of industrial waste Protective clothing is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in...

Страница 6: ...the following British Standards BS 715 BS 1251 BS 1289 Part 1 BS EN 1806 BS 4543 Part 2 BS 5440 Part 1 BS 5440 Part 2 BS 5871 Part 1 BS 6461 Part 1 BS 6891 In England and Wales the current edition of...

Страница 7: ...nce from the base of the fireplace opening in the wall to the finished floor level is at least 72mm 3 2 2 To a fireplace incorporating a metal flue box conforming to BS715 with a minimum internal dept...

Страница 8: ...fire surround or marble to reduce the opening This may cause cracking of the surround back or marble 3 3 The following flues are suitable 225mm x 225mm conventional brick flue If a flue liner is used...

Страница 9: ...imney which was previously used for solid fuel the flue must be swept clean prior to installation All flues should be inspected for soundness and freedom from blockages 3 8 If the fireplace opening is...

Страница 10: ...n extractor fan may only be used in the same room as this appliance or in any area from which ventilation for the appliance is taken if it does not affect the safe performance of the appliance Note th...

Страница 11: ...l surround is used as a template to mark the area for combustible cladding removal and that this area is increased by at least 2mm all round 3 18 The minimum allowable distance from the outside of the...

Страница 12: ...shut the appliance down if an unacceptable amount of harmful products of combustion accumulate Under no circumstances should the A S D be altered or bypassed in any way Only a genuine manufacturers r...

Страница 13: ...carefully to prevent damage Take special care when handling the ceramic components Some items may be contained in the packaging fitments Examine the packaging carefully before discarding Check that a...

Страница 14: ...gether with secondary fixing to the fireplace floor The methods are detailed in section 9 of this manual Before selecting the retention method consult with the customer Method 2 is provided for instan...

Страница 15: ...performs satisfactorily Fit the battery to the ignition block located below the burner tray at the left side see figure 7 The positive terminal is to the top as you insert Depress the slider control a...

Страница 16: ...e different for fireplaces with conventional brick flues and precast flues 2 Place the template on the fireplace floor printed side upward with the front line level with the front surface of the firep...

Страница 17: ...removing the shouldered screw which joins the control linking bar to the control pivot unit See figure 9 3 Detach the burner unit from the convector box by removing two screws See figure 10 Lift the b...

Страница 18: ...lider arm using two of the screws supplied in the bag containing the extension bracket Attach the slider knob to the slider extension bracket using the other two screws supplied in the bag containing...

Страница 19: ...rround area is sound enough to take the rawlplugs and woodscrews If necessary make sound with a suitable cement 2 Place the convector box centrally in the fireplace in the position in which it is to b...

Страница 20: ...e the convector box unit close to the fireplace but allow sufficient access into the fireplace opening so that the cables can be threaded through the eyebolts and returned through the back of the conv...

Страница 21: ...plugs supplied Fit a woodscrew in each plug and tighten 12 Inspect the installation of the convection box against the fireplace surround If the convection box is aligned squarely and the sealing is sa...

Страница 22: ...Burner Checks Some burner operations can be checked at this stage Checking now will mean that less disassembly will be required if any problems are found A full check should still be made however afte...

Страница 23: ...he inlet T connector See figure 25 Check the pressure with the appliance alight and set at maximum output 2 After checking turn off the appliance Remove the pressure gauge and replace the test point s...

Страница 24: ...ox Pull the coal forward so that it locates immediately behind the front rim of the firebox See figure 29 The front base coal will touch the rear base coal as it is located There are two types of loos...

Страница 25: ...coals The letter B should be upright The coal should touch the right side of the firebox See figure 33 7 Place the remaining type A coal between the front and rear base coals The letter A should be up...

Страница 26: ...ormal with new appliances They are totally harmless and will disappear after a few hours use 14 1 1 Lighting the burner 1 Make sure the slider button is at the off position At topmost position marked...

Страница 27: ...s 4 Place the smoke match tube into the convection box at the right hand side and immediately below the black top cross member Angle it at approximately 45 to the horizontal Insert the tube so that th...

Страница 28: ...ficient oxygen due to spillage or poor ventilation Check that the system operates properly as follows 1 Light the appliance Set the slide control to the maximum burning position and leave for one minu...

Страница 29: ...est setting This will also burn off any carbon deposits that may have formed during previous use If using the appliance for long periods it is beneficial to change between settings This will also help...

Страница 30: ...clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when...

Страница 31: ...lly closing it and observing that there are sparks at the pilot electrode 17 3 To Remove the Gas Shut Off Microswitch See figures 39 40 41 The gas shut off microswitch is stamped V4NT9C2YCGPX or V4NT9...

Страница 32: ...round clear and place carefully aside 5 Refit in the reverse order Make sure that the surround is properly located over the upper retaining brackets See section 11 of this manual for detailed fitting...

Страница 33: ...n 17 6 2 Detach the thermocouple from the interrupter block by unscrewing the thermocouple nut 3 Detach the two microswitch leads from the interrupter block 4 Remove the interrupter block by unscrewin...

Страница 34: ...om the interrupter block the microswitch lead terminals in the interrupter block will be loose Make sure that they are properly secured to give a good electrical contact when retightening the thermoco...

Страница 35: ...hed the microswitch leaf against the microswitch body When refitting the thermocouple and interrupter block make sure that the microswitch wires are properly secured to give a good electrical contact...

Страница 36: ...o Remove the Main Burner Injector See figure 53 1 Remove the burner See section 17 12 2 Remove the burner clamping screw See figure 53 3 Unscrew the injector from the burner 4 Refit in the reverse ord...

Страница 37: ...Page 37 INSTALLER GUIDE...

Страница 38: ...18 SHORT LIST OF SPARES Page 38 INSTALLER GUIDE...

Страница 39: ...tural Gas Appliances 1 3002988 Pilot injector For Propane Gas Appliances 5108552 G Injector Stereomatic Cat 82 074 For Natural Gas Appliances 1 5108136 Injector Stereomatic Size 132 and carrier For Pr...

Отзывы: