8
3.
GENERAL
3.1.
Approvals & codes
These appliances are certified by C.S.A. for use in Canada and the USA. These appliances are for installation directly venting
through an outside wall or through the roof.
Model 535XAN is for use with natural gas.
Model 535XAP is for use with propane. It can be converted for use with natural gas with kit #608NGK.
These appliances comply with
CGA P.4.1, Testing method for measuring annual fireplace efficiencies.
The installation must conform with local codes or, in the absence of local codes with the
National Fuel Gas Code, ANSI
Z223.1
or the
Canadian installation code CAN/CGA-149
. Only qualified licensed or trained personnel should install these
appliances.
These appliances, when installed, must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA 70
or the
Canadian Electrical Code, CSA C22.1.
3.2.
Ratings
Model
535AN 535AP
Gas Natural
Propane
Altitude (Ft)
0-4500
1
Input Max. (Btu/h)
30,000
28,000
Input Min (Btu/h)
6,500
14,500
Manifold pressure (in.w.c.)
3.5-3.9
10.3-10.7
Min. Supply pressure (in. w.c.)
5.0
11.0
Max. Supply pressure (in. w.c.)
10.5
14.0
1
Tested to
CAN/CGA - 2.17 Gas fired appliances for use at high altitudes
. In the USA, installations may require deration over
2000ft - Check local codes.
3.3.
Wall Thickness
The vent system (when horizontally terminated) is approved to pass through combustible wall construction of up to 14”
(36cm) thick.
A non-combustible wall can be any thickness up to the maximum horizontal run of vent pipe allowed for the particular
installation – See section 4.