(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the 

manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for 

venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the 

manufacturer: 

 

1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation 

instructions; and  

 

2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall 

include a parts list and detailed installation instructions.  

 

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, 
all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with 
the appliance or equipment at the completion of the installation. 
 

Содержание 535XAN

Страница 1: ...the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufa...

Страница 2: ...Support 18 7 8 Attaching to the Framing 18 8 INSTALLATIONS WITH HORIZONTAL TERMINATION INSTALLING TO WALL 19 8 1 Wall Opening 19 8 2 Valor Terminal 551DVK Preparing Wall Plates 19 8 3 Dura vent Termin...

Страница 3: ...ept free from obstructions No objects should be placed within 2 feet 60cm of the vent terminal The terminal is hot during operation and requires a guard if it is accessible to any person An approved V...

Страница 4: ...said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with...

Страница 5: ...structions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system sha...

Страница 6: ...cess through the appliance It may be fitted before the fireplace is installed or retrofitted at a later date Kit 755CFK Natural Gas For conversion from propane to Conversion kit natural gas Intended p...

Страница 7: ...clearance B 7 178mm 8 203mm 9 229mm 10 254mm 11 279mm 12 305mm 14 356mm Figure 1 Major dimensions clearances without optional trims Shown with 601SFB Front 3 sided trims 4 sided trims Figure 2 601SFB...

Страница 8: ...ppliances when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CS...

Страница 9: ...the framing stage and fixed to the framing using the support angles Wall finish cement board above is then installed over the support angels up to the black frame on the unit Be aware of the area 9 x...

Страница 10: ...ith either 551DVK standard vent kit or another terminal cap and accessories Adapter 817VAK one 90 vent elbow and pipe lengths will be required See venting options section of this manual The location r...

Страница 11: ...ermination The dimensional requirements in sections 4 2 and 4 3 apply Adapter 817VAK one 90 vent elbow and pipe lengths will be required A thimble kit may also be necessary See venting section of this...

Страница 12: ...ps a vertical vent terminal roof flashing and pipe lengths will be required Various other ceiling or roof items may be necessary depending on the particular installation See venting options section of...

Страница 13: ...n on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Clearance to unventilat...

Страница 14: ...Screws for vent fixing 4 Woodscrews for fixing appliance to studding 1 Deluxe remote control 601SFB Standard metal front Alternative 1 Upper louver unit 1 Lower louver unit 2 Side channels 2 Hinge stu...

Страница 15: ...15...

Страница 16: ...top right corner of the window Carefully lift the window away Keep the window and bolts in a safe place 7 2 Ignition Spark Check The pilot burner and electrode unit is at the left end of the burner Pu...

Страница 17: ...the shield to the case sides by refitting the two screws at the top rear corners and by two screws from the pack fitted near the front Bend the two top rear stand offs and fit to the heat shield with...

Страница 18: ...ertical rise of 3ft or more fit the restrictors at maximum port opening position See Graph 2 On models 535 the horizontal type restrictors are never set at any position except maximum port opening 7 6...

Страница 19: ...all plate over the terminal unit 3 Slide the terminal into the wall Make sure that the drain hole is at the bottom the seam will be through the notch in the wall plates See figure 24 4 Slide the inner...

Страница 20: ...igure 24B Figure24C 8 3 Terminals Installing to wall Unless the wall is totally non combustible fit wall thimbles Install as detailed in the manufacturer s instructions supplied with the pipes Figure...

Страница 21: ...through the roof If directly above the position where it penetrates the ceiling drop a plumb from the roof to the small hole in the ceiling and mark the roof at this spot If rafters or other obstructi...

Страница 22: ...p and slot in the board is inline with the tab on the wiring harness plug Connect wires A with the L terminals to the connectors B on the control valve Please note that the connectors are different si...

Страница 23: ...m the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5kPa f Failure...

Страница 24: ...e two top projections in the ash bed into the holes in the rear log See figure 40 3 Place the front log at the front of the firebox as shown in figure 41 4 Place the right side center log in position...

Страница 25: ...d all other controls wall switch remote hand unit See owner s lighting instructions further on in this manual for full details Aeration adjustment As described in section 11 for natural gas appliances...

Страница 26: ...o adhesive backed magnet counter plates to the tabs at the firebox sides which line up with the magnets on the lower louver See figure 48 Fit the two side channels by hooking into the openings at the...

Страница 27: ...Use this setting when you want a particular flame level For instance you want to watch flames burn at their highest level and you don t mind if the room is too hot Here s what you do 1 Press either of...

Страница 28: ...n will allow The window should be open enough to let you clean the inside of the glass See figure 62 Always securely fasten the window before lighting 16 3 Clean the Ceramic Fuel Effects Firebox Walls...

Страница 29: ...nually 16 5 Servicing All appliances use four 1 5V AA batteries for thermostat control For Appliances with Wall switch only the batteries are accessible by opening the bottom access panel For Applianc...

Страница 30: ...G INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF...

Страница 31: ...982 4DT ST14 TERMINATION CAPS SNORKEL 36 Rise 981 4DT ST36 UNIVERSAL ADAPTER 3 FLEX COUPLER 2150 CO LINEAR FLEX CONNECTOR 923F CO AXIAL TO CO LINEAR ADAPTER 923GCL 556CLA VENT ADAPTERS COUPLERS CO LI...

Страница 32: ...FLASHING 0 12 6 12 943 4DT AF6 SV4FA ROOF FLASHING 7 12 12 12 943S 4DT AF12 SV4B FLASHINGS FLAT ROOF FLASHING 943F SV4F WALL THIMBLE 942 4DT WT SV4RSM STORM COLLAR 953 4DT SC SV4AC DECORATIVE PLATE 9...

Страница 33: ...n and building codes 1 3 Owner must comply with all operating instructions 1 4 This warranty is only valid under normal non commercial conditions of use and service This warranty is void if there is e...