Manufactured by Miles Industries Ltd., British Columbia, Canada
16
5.2.6.
Corner location, rear vent
connection, vertical rise,
horizontal termination
(Figs 24 & 26)
Can be used with either #551DVK standard
vent kit or #984 Dura-vent terminal cap and
accessories.
Adapter #817VAK, two 90° vent elbows
#990B and Dura-vent pipe lengths will be
required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
All vertical dimensional limits are as section
5.2.3.
The minimum corner location is shown in
fig. 26.
5.2.7.
Rear vent connection, vertical
vent rise with through the roof termination (Fig.27)
Figure 26
Adapter #817VAK, one 90° vent elbow #990B, Dura-vent pipe lengths, a vertical vent terminal and roof flashing will be
required. Various other ceiling or roof items may be necessary depending on the particular installation (See venting options
section of this manual).
5.2.8.
Rear vent connection, vertical vent rise with offset and through the roof termination (Fig.28)
For situations where offset is necessary in an attic to avoid obstructions or allow useful space.
Adapter #817VAK, one 90° vent elbow#990B, two 45° vent elbows #984, wall straps, a vertical vent terminal, roof flashing
and Dura-vent pipe lengths will be required. Various other ceiling or roof items may be necessary depending on the particular
installation (See venting options section of this manual).
Figure 28
Figure 27