Figure 15
4.2.13.
Top vent connection, corner
location, vertical rise,
horizontal termination, 45°
pipe bend (Figs 13 & 15)
Can be used with either #551DVK standard
vent kit or #984 Dura-vent terminal cap and
accessories.
Adapter #817VAK, one 90° elbow #990B,
one 45° elbow #945B and Dura-vent pipe
lengths will be required. (See venting
section of this manual).
All vertical dimensions and clearance limits
are as section 4.2.10.
The minimum corner location is shown in
fig. 15.
4.2.14.
Top vent connection, corner
location, vertical rise, straight
horizontal termination (Figs
13 & 16)
Figure 16
Can be used with either #551DVK standard
vent kit or #984 Dura-vent terminal cap and
accessories.
Adapter #817VAK, one 90° elbow #990B
and Dura-vent pipe lengths will be required.
(See venting section of this manual).
All vertical dimensions and clearance limits
are as section 4.2.10.
The minimum corner location is shown in
fig. 16.
4.2.15.
Top vent connection, vertical
vent rise, through the roof
termination (Fig. 17)
Adapter #817VAK, Dura-vent pipe lengths,
a vertical vent terminal and roof flashing
will be required. Various other ceiling or
roof items may be necessary depending on
the particular installation (See venting
options section of this manual).
Figure 17
Manufactured by Miles Industries Ltd., British Columbia, Canada
11