7. CONTROL AND PRESSURE CHECKS
7.1 Check control settings.
1.
If closed
,
open the isolating valve at the inlet ‘T’ connector.
2.
To check the control positions temporarily place the fascia loosely over the engine.
Fit the control knob over the gas tap spindle.
3.
Depress the control knob and
slowly
turn anticlockwise partially towards the 1/IGN
position until some resistance is felt. Keep depressed at this position for a few
seconds to purge air from the system then, while keeping it depressed, turn fully to
the 1/IGN position. A spark should be generated at the pilot while turning. The spark
should ignite the pilot. If it does not, keeping the knob depressed, continue to
slowly
turn the knob anticlockwise. A
second spark
should be generated at the pilot while
turning. This spark should ignite the pilot.
4.
When pilot ignition has been achieved, keep the control knob depressed for
approximately ten seconds to allow the thermocouple probe to warm up and then
release it. If the pilot does not remain alight, ensure that the air has been purged, that
the pilot orifice is clear and that the thermocouple connections are sound. Replace
the pilot unit if necessary (See servicing section of this guide).
5.
Check all the control settings. These are: -
7.2 Flame supervision and spillage monitoring system.
The pilot unit incorporates a system that will automatically shut off the gas supply if
the pilot flame goes out or if there is insufficient oxygen due to spillage or lack of
ventilation.
Check that the system operates properly as follows:
1.
Light the appliance. Set at position 5 and leave for one minute.
2.
Turn back to “OFF” to extinguish the pilot.
Note the time when the pilot goes out.
Listen for a snap sound at the gas tap.
Note the time when the sound is heard.
An
electromagnetic valve shutting off the gas supply through the tap causes this sound.
The valve is located in the body of the tap. The valve should operate
within 60
seconds of the pilot going out.
If the valve does not operate within this time limit do
not allow the appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of
operation.
This monitoring system, or any of its parts, must only be exchanged using
Valor Fires authorised parts.
Page 22
©
GDC Group Limited 2014.
INSTALLER GUIDE
Control Knob
Position
Radiants Condition
2
Centre radiants on low. Outer radiants off.
3
Centre radiants fully on. Outer radiants off.
4
Centre radiants fully on. Outer radiants on low.
5
All radiants fully on.
Содержание 347 Helmsley
Страница 4: ...Page 4 GDC Group Limited 2014 INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 29 TO 44 INSTALLER GUIDE...
Страница 29: ...Page 29 GDC Group Limited 2014 OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 37 TO 44...
Страница 39: ...Page 39 GDC Group Limited 2014 OWNER GUIDE...
Страница 40: ...GDC Group Limited 2014 Page 40 OWNER GUIDE...
Страница 41: ...Page 41 GDC Group Limited 2014 OWNER GUIDE...
Страница 42: ...GDC Group Limited 2014 Page 42 OWNER GUIDE...