Valor Fireplaces • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1
Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333
www.valor
fi
replaces.com
December 2019
1/3
Cement Board
L2 1700K
Min. 60” [1524 mm]
Min. 44-1/2” [1130 mm]
A
D
D
E
B
C
Flush with bottom of unit;
add extra cement board
to overlap framing.
Joints preferred at corners
to prevent cracking
Minimal coverage area of non-combustible cement board.
Any
wall
ȴQLVKDSSOLHGWRVKDGHGDUHDPXVWEHQRQFRPEXVWLEOH
Linear 1700 outline
LQFOXGLQJVWDQGRV
Non-combustible
cement board
required thickness:
1/2” [13 mm]
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULTEZ LE GUIDE D’INSTALLATION
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULTEZ LE GUIDE D’INSTALLATION
Material Speci
fi
cations
Non-Combustible
Material which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or any combination
thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750°C shall be considered
non-combustible materials.
Combustible
Materials made of or surfaced with wood, compressed
paper, plant
fi
bers, plastics, or other material that
can ignite and burn, whether
fl
ame proofed or not,
or plastered or unplastered shall be considered
combustible materials.
Non-Combustible Cement Board
The L2 Linear
fi
replace requires a 1/2” (13 mm) thick
non-combustible cement board to be used as a wall
surface immediately surrounding the unit’s opening—
see diagram for minimum coverage.
Extending the cement board well beyond the minimum
shown will help avoid cracking due to di
ff
erential
expansion of materials.
Pre-drill cement board with oversized holes and do
not over-tighten screws to avoid cracking due to heat
expansion.
Standard gypsum wall board may be used beyond the
perimeter of the cement board.
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULTEZ LE GUIDE D’INSTALLATION
inches [mm]
With 1750 or
1775 trims
with 1730CIK kit
A
Min. 20-1/2 [521] Min. 20-1/8 [511]
B
14-3/4 [375]
15-13/16 [401]
C
Min. 9-1/4 [235]
Min. 8-9/16 [218]
D
Min. 5 [127]
Min. 4-1/2 [114]
E
Min. 50 [1270]
Min. 51-1/16 [1296]