Wall Finish — Avoid Cracking

Avoiding Cracking Wall Finishes

We recommend installing the optional HeatShift 

System to reduce the wall temperatures and minimize 

the possibility of cracking wall 

fi

 nishes.

If a clean 

fi

 nish with no tile, etc. is desired, joints in the 

cement board and the transition to gypsum board 

will require special attention if future cracking is to be 

controlled. Be aware that temperatures on the non-

combustible wall surface above the appliance can 

exceed 200°F (93°C). 
Below are some tips on how to best avoid any cracking:

• Allow materials to dry thoroughly before 

fi

 nishing the 

wall. Cement board has the ability to absorb up to 30 

percent of its weight in water and may shrink as much 

as 1/8” over a 48” length when drying from a satu-

rated condition. Running the 

fi

 replace for an extended 

period before 

fi

 nal 

fi

 nishing will help drive out mois-

ture.

WARNING

HeatShift System MUST be installed on 

this appliance when using 1730CIK—Clean 

Installation Kit.

• Always pre-drill screw holes through cement board 

and use screws speci

fi

 c for material used.

• Always use mesh tape over joints.

• Always stagger joints in wall board.

• Behind joints, double up studs or use studs “on the 

fl

 at” to add extra support to the joint. Adhesive on 

the backside of wall board behind any joints can help 

control di

 erential movement.

• Use multiple, thinner coats of joint compound and al-

low to dry thoroughly between coats.

• Ensure framing materials are dry.

• After 

fi

 nishing the wall, introduce heat gradually to 

slowly dry any excess moisture rather than drying too 

fast.

• Avoid notching cement board or tiles around corners 

of window opening and instead provide a joint that 

intersects the corner.

• Avoid using lage one-piece slab of material with a 

cut-out in the middle as a surround for the 

fi

 replace. 

Expansion above the opening will cause cracking at in-

side corners. Provide a joint that intersects the inside 

corner to avoid cracking.

Cracks

Provide joints 

either here or 

here