background image

17

 Lighting Instructions

FOR YOUR SAFETY, READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a 

fi

 re or explosion may result 

causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand, remote control, or wall switch. Follow these instructions 

exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.

B. 

BEFORE LIGHTING

, smell all around the appliance area for gas. Be sure to smell next to the 

fl

 oor because 

some gases are heavier than air and will settle on the 

fl

 oor.

WHAT TO DO IF YOU  SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electric switch; do not use any phone in your building.
•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the 

fi

 re department.

C. Use only your hand to push in or turn the control knobs. Never use tools. If the knobs will not push in or turn by 

hand, don’t try to repair them; call a quali

fi

 ed service technician. Force or attempted repair may result in a 

fi

 re or 

explosion.

D. Do not use this appliance if any part has been under water. Immediately call a quali

fi

 ed service technician to 

inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

LIGHTING INSTRUCTIONS

1. 

STOP!

 Read the safety information above.

2. 

TO CLEAR ANY GAS, turn main valve off by pressing OFF (red dot) button on remote 

handset (1).

• Wait 

fi

 ve (5) minutes to clear out any gas, then smell for gas, including near the 

fl

 oor. 

If you 

smell gas, STOP!

 Follow “B” in the safety information above on this label. If you don’t smell 

gas, go to the next step.

3.  

AUTOMATIC IGNITION: 

MAN-knob (2) in ON position. Ensure Flame Adjustment 

knob (3) is set to lowest setting (

)

 

(Fig. 1). Locate the pilot (Fig. 3.) inside of 

fi

 rebox at left hand side.

•  On the remote control handset, press the OFF button (red dot) and large 

fl

 ame 

button (

) simultaneously; a short acoustic signal con

fi

 rms the start has begun.

•  Further short acoustic signals indicate the ignition process is in progress.
•  When the pilot is lit, the Flame Adjustment knob (3) will automatically rotate to 

the highest setting.

•  Press the small 

fl

 ame button (

) on the remote control handset to reduce the 

fl

 ame height.

4.  

MANUAL IGNITION: 

MAN-knob (2) in MAN position

 

(Fig. 2). With the window 

off, locate the pilot (Fig. 3) inside of 

fi

 rebox at left hand side.

•  Set Flame Adjustment knob (3) to the lowest setting (

).

•  Push down the metallic core (4) with a pen or similar instrument; this will establish 

the pilot gas 

fl

 ow.

•  Light gas at the pilot (5) with a match.
•  Continue holding down metal core (4) for about 10 seconds; after release, pilot 

should remain lit.
•  If the pilot will not stay lit after several tries, turn the gas control knob (3) to OFF (

) and call your local 

service technician or gas supplier.

•  Reinstall the window and set the MAN-knob (2) to ON; turn Flame Adjustment knob (3) up (

) or down (

manually or use the 

fl

 ame buttons (

)(

) buttons on the remote control handset to adjust the 

fl

 ame height.

 

TO TURN OFF  GAS TO APPLIANCE

AUTOMATIC SHUT-OFF

 (using the remote control handset):

•  Press and hold the small 

fl

 ame button (

) on the remote control handset to shut-off the main burner gas 

fl

 ow.

•  Press OFF button (red dot) on remote handset to shut-off the appliance, including pilot 

fl

 ame.

Spark

Pilot

Fig 3

5

Fig 1

Fig 2

1

OFF

OWNER’S 
INFORMATION

Содержание 1700JN

Страница 1: ...ble en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Страница 2: ...arbon Monoxide Detector requirements on page 18 Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www...

Страница 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Страница 4: ...ysical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk in...

Страница 5: ...cularly the GLASS window DO NOT LET CHILDREN touch the glass or any parts of your fireplace even after it is turned off as it is still hot USE THE BARRIER SCREEN provided with the trim or a GATE to re...

Страница 6: ...ducts with varying results The following are recommendations only and are not meant to guarantee results NOTE This is a problem beyond Miles Industries control and is not covered under warranty Clean...

Страница 7: ...When cleaning make sure that no par ticles are brushed into the slots of the burner To refit the window 1 Place the window in its bottom railing Ensure to remove any vermiculite glass or shale particl...

Страница 8: ...periodic check of the pilot and burner flames should be made Check after the fire has been on for at least 30 minutes The pilot flame must cover the tip of the thermocouple probe The main burner flame...

Страница 9: ...ription when requesting spare parts To replace the batteries The battery compartment is located next to the wall switch in the vicinity of the fireplace Its front plate is attached with magnets to the...

Страница 10: ...s is off when the handle is perpendicular with the pipe How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following methods to ensure that your fireplace will n...

Страница 11: ...confirm the ignition is in process Once pilot ignition is confirmed there is main gas flow After main burner ignition the handset will automatically go into manual MAN control mode Press OFF button Wh...

Страница 12: ...he hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode...

Страница 13: ...programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERATURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Te...

Страница 14: ...TIMER moon while the time flashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minu...

Страница 15: ...ge in flame height for a period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appli ance will continue to work...

Страница 16: ...Shale Set Liners choose one 1715FBL Linear Fluted Black Liner Set 1725RGL Linear Reflective Glass Liner Set Add 1725RGL 3 Glass Retainer Kit Trims choose one Barrier Screen 1750 Linear 5 1 4 Surround...

Страница 17: ...oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION MAN knob 2 in ON position Ensure Flame Adjustment knob...

Страница 18: ...d a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions sh...

Страница 19: ...ded with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list a...

Страница 20: ...Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 For installations at elevations above 4 500 feet 1 370 m in Canada please consult provincial and or local authorities having jur...

Страница 21: ...ag ge 23 WARNING Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other item...

Страница 22: ...3 mm 386 18 5 8 473 mm 3 3 4 95 mm 4 102 mm 20 508 mm 32 3 8 822 mm 33 1 8 841 mm 14 1 2 2 369 m mm 9 3 8 238 m mm 52 1321 mm 49 11 16 1262 mm 1270RBK Remote Blower Kit outlet remove plate LDK Duct Ki...

Страница 23: ...Face of Cement Board Mantel Height from Bottom of Unit Fireplace Opening Ceiling 24 Min to Ceiling 44 42 40 38 23 7 8 9 3 8 4 minimum to combustible or non combustible hearth Note Use of the optional...

Страница 24: ...24 49 11 16 Fireplace Opening Wall Min 4 to wall or combustible mantel leg Face of Finished Wall FIREPLACE Combustible Sidewall Mantel Leg Top View Mantel Hearth Clearances QUALIFIED INSTALLER...

Страница 25: ...GUIDE D INSTALLATION NON COMBUSTIBLE MATERIALS ONLY READ INSTRUCTIONS MAT RIAUX INCOMBUSTIBLES SEULEMENT CONSULTEZ LE GUIDE D INSTALLATION Min 60 1524 mm 50 1270 mm Min 44 1 2 1130 mm Min 20 1 2 521 m...

Страница 26: ...ox 10 3 4 274 mm from back surface of wall finish to front surface of appliance case w no vent offset 15 3 16 386 mm 14 1 2 369 mm 9 3 8 238 mm 19 1 4 489 mm Fireplace Opening PARTIAL SHELF top outlet...

Страница 27: ...Dimensions of venting are based on using Dura Vent elbows Elbow curve radius dimensions will vary when using other brands In general other brands have slightly bigger radius Minimum 12 inches vertica...

Страница 28: ...sembly up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Framing Vent in Combustible Wall...

Страница 29: ...MBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION PIPE LENGTH 90 ELBOW 90 ELBOW Co axial...

Страница 30: ...e and run can be used as long as they are within the allowable limits shown on the chart below 5 A maximum of 4 x 90 degrees elbows or equivalent 2 x 45 degrees 90 degrees can be used Excludes the 45...

Страница 31: ...of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restriction is based on laboratory tests The ide...

Страница 32: ...bly located within 15 feet 4 6 m below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet...

Страница 33: ...two lengths of 2 ply flexible chimney liner one 3 diameter liner for intake and one 4 diameter liner for exhaust both approved for venting gas appliances a 3 x 4 co linear termination kit and flashing...

Страница 34: ...on For installation of the adapter to the appliance see the instructions supplied with the 1156CLA Co linear Venting Example of co linear terminal configurations 9 3 8 11 11 16 3 exhaust collar 1 1 2...

Страница 35: ...sories trim decorative lighting etc will be installed with this fireplace The venting configuration 2 Unpack the appliance removing all items packed inside and around the appliance 3 Check that you ha...

Страница 36: ...nal LDK Duct Kit s take off collars to appliance if used See installation instructions packed with the LDK kits for details Fit the Appliance into Framing 1 Remove the 4 screws retaining the engine to...

Страница 37: ...terials Pre drill cement board with oversized holes and do not over tighten screws to avoid cracking due to heat expansion Standard gypsum wall board may be used beyond the perimeter of the cement boa...

Страница 38: ...appliance can exceed 250 F Below are some tips on how to best avoid any cracking Allow materials to dry thoroughly before finishing the wall Cement board has the ability to absorb up to 30 percent of...

Страница 39: ...red and the duplex receptacle will need to be split to ensure separate control of fan and lighting The duplex receptacle and box must be located as per these instructions Wiring within this box must h...

Страница 40: ...ion against sulfur compounds Unions in gas lines should be of ground joint type The gas supply line must be sized and installed to provide a supply of gas sufficient to meet the maximum demand of the...

Страница 41: ...the warranty Consult your dealer in case of damages Pressure Test Points The minimum supply pressure is given in the section Specifications of this manual page 20 All piping and connections must be te...

Страница 42: ...wards the middle to fit into the middle section Place the panel s right section on the ledge above the ports of the rear of the firebox The section sits on the ledge behind the tabs with its plain edg...

Страница 43: ...the side panel anchors on each side of the firebox 9 Place the remaining rear panel s section behind the left side panel and fit its stepped edge to the stepped edge of the rear panel s center section...

Страница 44: ...possible to maximize the air gap behind the burner 2 Fill a small container with the equivalent of approximately 3 cups 750 ml of vermiculite from the bag supplied 3 Carefully spread the vermiculite...

Страница 45: ...the log s left peg in the front hole for natural gas NG fire LPG fire Place the log s left peg in the rear hole for propane gas LPG fires 2 Place the rear left log as indicated 3 Place the front left...

Страница 46: ...6 Place centre cross log to rear log as indicated Pivot tail end so tip is just inside fireplace window line 7 Some vermiculite may be added outside the burner on the platform if desired 8 Place the r...

Страница 47: ...t supplied Murano Glass Fire Kit which contains 1 bag of clear fireglass 8 pieces glass panels Installation Carefully unpack the kit 1 Install the steel platform around the burner as indicated The ope...

Страница 48: ...n the burner one at each end and one in the middle as indicated The rocks should not sit on top of the burner ports but can overhang slightly Note Although these rocks can be installed after the shale...

Страница 49: ...ree rocks Do not overfill 3 Install some of the rocks around the shale bed according to the image shown below Note Some of the rocks may overhang slightly over the burner edge 4 Add the twigs to the r...

Страница 50: ...ut any rock on the pilot shield Do not put more rocks on the shale The acceptable variations are only for rocks installed on the black platform outside of the shale bed or pilot shield Pilot shield Su...

Страница 51: ...as indicated Hot Glass Warning Plate WARNING Failure to install the window correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in...

Страница 52: ...th Velcro bands 1 Pull out the receiver from its location to connect the battery holder and wall switch 2 Feed the white connector end of the harness assembly through side holes in fireplace liner bod...

Страница 53: ...battery cover assembly 12 Position battery holder to rear face and secure together with cable tie note clearance is required for battery snap connection 13 Make the snap connection load 4 AA alkaline...

Страница 54: ...flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 11 15 Set Aeration if necessary Light the fire an...

Страница 55: ...his holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder to the wall find a con...

Страница 56: ...56 Wiring Diagram Wall Switch Kit GV60 Wiring Diagram Remote Battery Holder 4 AA Batteries 5 pin connector 9 Volt connector QUALIFIED INSTALLER...

Страница 57: ...M CFAA3 95090390 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL6 TM 4CAA6 4DCAB336 1156CLA5 6 9401064336 Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Fle...

Страница 58: ...SK 949606001 Masonry Flashing TF 4MF New Siding Flashing 658NSFK Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT 949064U Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC 9496...

Страница 59: ...r damage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances ii...

Страница 60: ...Gaskets module plate long 2 3000400 34 Gaskets module plate short 2 3000399 35 Pilot sealing plate 4002910 36 Valve to elbow pipe assembly 4003749 37a GV60 valve assembly NG 4003986 Code Description P...

Страница 61: ...69 White beach pebble 2 4003084 70 Black beach pebble 2 4003085 71 Small beige beach pebbles 2 4003087 72 Grade 1A vermiculite bagged 4002940 73 Hot glass warning plate 4003093 74 Rocks Shale Set 171...

Страница 62: ...1 2 3 89 89 4 4 5 6 11 12b 9 13 14 73 8 10 90 12a 53 51 50 52 49 50a 50a 53 15a 15b 16 18 19 20 26 27a 27b 28a 28b 29 30 31 32 33 34 35 37a 37b 36 39 38 47a 47b 47c 47d 47e 47f 47g 47h 47i 7 7 Spare...

Страница 63: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Страница 64: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Отзывы: