Safety and Warning Information

State of California. Proposition 65 Warning.

Fuels used in gas, wood-burning or oil fired appliances, and the products of combustion of such fuels, contain 

chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. 

California 

Health & Safety Code Sec. 25249.6.

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used 

in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where 

the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, 

including but not limited to decks and porches, the following requirements shall be satisfied: 

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal 

vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide 

detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. 

In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide 

detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side 

wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the 

services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, 

the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor 

level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the 

owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during 

said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance 

with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at 

a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally 

vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch 

in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not 

approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage 

installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. 

State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage Requirements

Operating your fireplace for the first time

When operating your new fireplace for the first time, some vapors may be released due to the burning of curing 

compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the flames 

to be the full height of the firebox, or even slightly higher, for the first few hours of operation. It is also possible that 

these vapors could set off any smoke detection alarms in the immediate vicinity. These vapors are quite normal on 

new appliances. We recommend opening a window to vent the room. After a few hours use, the vapors will have 

disappeared and the flames will be at their normal height.

Содержание 1200EAN

Страница 1: ...used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www va...

Страница 2: ...kept out of reach of children In the presence of children we STRONGLY RECOMMEND that you install in front of the fireplace a fire screen doors or to protect young toddlers a hearth gate see Options on...

Страница 3: ...ic Bricks 26 Ceramic Logs 27 Window Refitting 29 Initial Remote Control Set up 29 Decorative Lighting Electrical Installation 30 Operation Check Aeration Settings Adjustment 31 Window Skirt and Side D...

Страница 4: ...is installation manual NO OTHER vent system or component MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separ...

Страница 5: ...vel b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requireme...

Страница 6: ...venting system design or the venting system components and 2 A complete parts list for the venting system design or venting system d MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM NOT PROVIDE...

Страница 7: ...GA 2 17 91 High Altitude Standard in Canada This appliance is for direct vent installations This appliance complies with CGA P 4 1 Testing method for measuring annual fireplace efficiencies The instal...

Страница 8: ...Doors and Plates see Options 1200EAN Combustible Floor Framing See Framing Cement Board When the appliance is installed directly on carpeting tile or other combustible material other than wood floori...

Страница 9: ...of cement board 50 to underside of header Electrical for ambient light only Electrical for ambient light only Zero Clearance to Stand Offs at Top Gas x x 6 5 8 dia Venting Center Line 6 6 46 3 4 Zero...

Страница 10: ...el Clearances Bottom of Unit Face of Cement Board 0 2 4 6 8 10 12 50 45 43 41 39 36 33 28 Mantel Projection from Face of Cement Board Mantel Height from Bottom of Unit Fireplace Opening Firebox Height...

Страница 11: ...Wall Min 6 between edge of opening and wall Face of Cement Board Note Right Side Clearances are the same Shading denotes allowable location for combustible mantel legs Combustible Sidewall Mantel Leg...

Страница 12: ...safe can degrade due to heat take this into consideration when choosing materials General Hearth Considerations Top of Finished Hearth Must Be Flush With Bottom of Heater to accommodate some optional...

Страница 13: ...d with the engine This insulation board acts as a thermal break 2 Minimum hearth projection is determined by a combination of the height of the hearth above the surface of combustible floor or carpet...

Страница 14: ...above combustible floor 3 6 9 12 4 3 2 1 Surface of Combustible Floor or Carpet Bottom of fireplace Wood is Allowed Directly Below Fireplace Combustible Floor Allowed 2 616STK 617STK Leg Hearth Air G...

Страница 15: ...y surface directly in front of the unit which is at a height of less than 4 from the bottom of the unit must be non combustible See chart for minimum non combustible projection required to protect com...

Страница 16: ...center of the frame Simpson Dura Vent DV Venting Accessories Termination Caps 46DVA HC Standard Coaxial Horizontal 46DVA VC Standard Coaxial Vertical 46DVA VCH High Wind Coaxial Vertical 46DVA VCE Ext...

Страница 17: ...lked and weatherproofed in such a manner as to Prevent rain water from entering the wall from the weather side by adequately caulking the outer vent plate to the exterior wall surface Prevent moisture...

Страница 18: ...ating through the wall may be graded downwards slightly to prevent water migration 7 Co linear venting is not allowed 8 A restrictor is required for many installations see next section 2 4 6 8 10 12 1...

Страница 19: ...page shows the vent restrictor required relative to the length of the vent pipe Venting To install the restrictor 1 On an engine previously installed open the panels on each side of the window Remove...

Страница 20: ...ay be opened 12 30 C Clearance to permanently closed window recommended to prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal...

Страница 21: ...ies in receiver and remote control handset 16 Perform initial remote control set up Tools and supplies required Packing knife Claw hammer Screwdriver set Metric socket set Pliers Adjustable Wrench Sea...

Страница 22: ...damage see next page 6 Verify that you have all the components required for the installation including brick panels in separate carton surround doors fret andirons venting components and accessories...

Страница 23: ...screws on each side and slide the panel out from under the firebox 2 Screw the appliance to the floor with 4 countersunk wood or cement screws not provided 3 Reinstall the overlay panel sliding it in...

Страница 24: ...let connection is a 3 8 inch NPT female connector and is located on the left hand side of the firebox Use only new black iron or steel pipes or copper tubing if acceptable check local codes Note that...

Страница 25: ...o be disconnected for servicing The flex line and shut off valve are supplied loose to avoid damage during shipping Connect the assembly to the appliance as shown below Pressure Test Points The minimu...

Страница 26: ...in place 4 Place the top panel over the top edge of the rear and side panels Leave the panel to balance there until right hand side panel is installed 5 Hold the right hand side panel at an angle and...

Страница 27: ...inst the back of middle log support Pins for Top Left and Right Logs Touches here Pins for Middle Left and Right Logs Middle Log position on pins at each end 2 Place the Middle Log on the pins of the...

Страница 28: ...nd resting on the middle left and front logs 4 Place the narrow end of the Middle Left Log on the left pin of the middle log with its wider end resting on the front log Place on pin with log projectin...

Страница 29: ...be initially synchronized before the first use 1 Insert batteries in the remote control receiver and handset The receiver is located left of the control valve under the burner module 2 With a sharp o...

Страница 30: ...box to the junction box 6 In the junction box hardwire the harness to the electrical wire Refit the junction box cover Outside the firebox fit a cable clamp 7 Fit the cover plate to the wall not suppl...

Страница 31: ...e shutter to control primary aeration See the figures below The shutter is factory set to an aeration gap which will give optimum performance for the vast majority of installations In a few unusual in...

Страница 32: ...rature we recommend that the handset should be between 3 and 15 feet away from the appliance but not directly above it We also advise that the handset should be located away from any other heat source...

Страница 33: ...ed 3 Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry preferably cotton cloth Most paper towels and synthetic materials are abrasive to ceramic glass and should be avoided 4 Ou...

Страница 34: ...the window To replace the light bulb follow these steps 1 Turn off the decorative light wall switch 2 Locate the light fixture Loosen the screws of the glass cover retaining tabs 3 While holding the...

Страница 35: ...ention is required for your appliance contact your supplier quoting the model number It will be helpful if the appliance serial number can also be quoted This number is on the rating plate which is lo...

Страница 36: ...sing the remote control system for the first time the receiver and the handset must be synchronized See the section Initial Remote Control Set up on page 29 in this manual Turning your fireplace ON WA...

Страница 37: ...hold down both the and buttons until the display flashes Let go 3 Quickly press the button to set the hour and the button to set the minutes Note You must start setting the time while the display is f...

Страница 38: ...within a 6 hour period the appliance will go to Standby pilot mode Handset Receiver Match The remote control handset and receiver are programmed to function together In case of a replacement of the ha...

Страница 39: ...b 3 to lowest setting On the remote control handset press the OFF button and large flame button simultaneously a short acoustic signal confirms the start has begun Further short acoustic signals indic...

Страница 40: ...40 Wiring Diagram...

Страница 41: ...1235MTP 3 Sided Polished Trim 1237MFP 4 Sided Polished Trim 614CVI Arched Cast Surround 615CVI Cast Surround 616STK Arched Stone Trim 617STK Stone Trim Safety Screens optional 1205DSK Draw Screen Kit...

Страница 42: ...n for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not c...

Страница 43: ...tor Elbow 360 LPG 4001494 32 Valve to Burner Pipe Assembly 4001279X 33 Location Support Assembly 2 4001288X 34 Top Gasket 4001269 35 Bottom Gasket 4001363 36 Sealing Gasket 4001364 Spare Parts Code De...

Страница 44: ...001226 b Frontera Stone 4001321 c Inca Slab 4001322 d Black Slab 4001480 68 RH Panel a Victorian Red Brick 4001225 b Frontera Stone 4001325 c Inca Slab 4001326 d Black Slab 4001479 69 Overlay to cover...

Страница 45: ...12 13 14 15 16 17 18 11 56 55 63 69 72 19a 19b Pilot Assy 20a to 27 28a 28b 31a 31b 33 Module Plate Gaskets 34 to 37 39 40 42 43 58 59 60 61 62 38 44 45 71 72 47a 47b 48 49 50 51 52 53a 53b 54 64 65...

Отзывы: