Checks
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
Light fi xture without glass cover
100W Halogen Light Bulb (119mm)
Light Bulb Replacement
The appliance is equipped with a
decorative light inside the fi rebox
located in front of the window. To
replace the light bulb, follow these
steps:
1.
Turn off the decorative light wall
switch.
2.
Locate the light fi xture. Loosen the screws of the
glass cover retaining tabs.
3.
While holding the glass cover so it does not fall and
shatter, swivel one or both of its retaining tabs to
free the glass. Gently remove the glass cover.
4.
Remove the light bulb from its socket by pushing
towards one end.
5.
With a gloved hand, replace with a new light bulb
using a 100 watts halogen 130 volts (type J T3,
119 mm long).
6.
Test the bulb by turning the wall switch on. Turn the
switch off again to complete the operation.
NOTE: If the bulb is new and not functioning, turn
off the dimmer switch and call your local electrician
for inspection.
7.
Put the glass cover back in place and, while
holding it, turn the retaining tab(s) to retain the
glass.
8. Tighten the tabs’ screws.
Correct Flame Picture
Pilot Flame can be
seen between logs
Owner’s Information
Pilot
Flame
Thermocouple
Probe must be
in Flame
Light fi xture with glass cover
Tab
Tab
Содержание 1200EAN