![Valor Heating Bauhaus Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/valor-heating/bauhaus/bauhaus_installers-manual_3265605024.webp)
INSTALLER GUIDE
Page 24
11.4
Remote Control Check
1.
Keep the pilot burner at the “main
burner on” position. Check the full range
of main burner heat settings using the
remote control handset.
In order to vary
the flame effect between High and Low
positions, press, and keep depressed,
either the High button, or the Low button
as appropriate (See figure 22).
The handset operates on ultrasonic principles, and as such it is not necessary to point it
directly at the fire.
2.
Use the handset to switch to the pilot only setting by depressing the Low button until
only the pilot flame remains alight.
3.
In order to disable the handset, but still leave the pilot alight, turn the pilot burner
control knob to the ignition position (
2
in figure 21).
4.
Turn the fire off by rotating the pilot burner control knob to the OFF position (
1
in
figure 21).
Figure 22 Remote control handset