![Valor Heating Bauhaus Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/valor-heating/bauhaus/bauhaus_installers-manual_3265605023.webp)
INSTALLER GUIDE
Page 23
•
To switch to the minimum aerated position slightly lift the control lever. A spring
mechanism will close the aeration shutter.
•
Please note : It is advisable to run the fire in its fully aerated mode (control knob
pushed in) at the beginning of each operation and if running at the minimum rate
setting, or to burn off any carbon deposits which may have built up after prolonged use
of the minimum aerated setting.
11.3
Manual controls check
1.
Ensure that the pilot burner control
knob is in the OFF position (
1
in
figure 21).
2
.
Depress the pilot burner control
knob and turn anti-clockwise to the
ignition position (
2
in figure 21) to
activate the piezo ignition system. A
‘click’ will be heard and the pilot
should light. Observe if it is alight by
looking through the slots to the left
hand end of the front coals. If the
pilot does not light immediately,
repeat the above procedure, keeping
the knob depressed for several
seconds in order to purge any air
from the system.
If after ten seconds, ignition has not occurred, turn the control knob back to the OFF
position. Wait 30 seconds and then repeat the ignition procedure.
3.
When the pilot is alight keep the knob depressed for ten seconds to allow the pilot
flame to stabilise.
4.
Release the knob. When the knob is released, the pilot should remain alight. If the pilot
fails to remain alight, repeat the ignition procedure, this time keeping the knob depressed
for a longer period of time.
5.
Once the pilot light is established, light the main burner by turning the pilot burner
control knob anti-clockwise to the “main burner on” position (
3
in figure 21), and by
then turning the main burner control knob to the high position (
5
in figure 21).
6.
Check the full range of heat settings by turning the main burner control knob slowly
between the high position and the low position (
4
in figure 21).
Figure 21 Appliance Manual Controls