time limit do not allow the appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of
operation.
This monitoring system, or any of its parts, must only be exchanged using Baxi
authorised parts.
7.3 Check reference pressure.
The appliance is pre-set to give the correct heat input at the inlet pressure shown in
section 3 of this manual. No adjustment is necessary.
7.3.1
Detach the control knob from the spindle. Remove the fascia.
7.3.2
Check the burner pressure by fitting a pressure gauge at the test point. The test
point is on the gas tap. Check the pressure with the appliance alight and set at
maximum output (Control position 5).
7.3.3
After checking, turn off the appliance. Remove the pressure gauge and replace
the test point sealing screw. Relight the appliance. Turn to the maximum output
position and test around the sealing screw for gas soundness with a suitable leak
detection fluid.
7.3.4
If all the above checks are satisfactory, continue with the installation. If not,
check the control and ignition circuitry and components as described in the servicing
section of this manual.
8. FASCIA FITTING
Before continuing with the installation of this appliance it is important that the
information contained on the back pages of the Owner guide is completed.
8.1 To fit the fascia.
8.1.1
Place the fascia over the engine.
Make sure that the top rear of the fascia
locates fully into the ‘U’ shaped notch of
the engine back panel (See figure 14).
8.1.2
Fit the control knob firmly on to the
control spindle.
8.1.3
Secure the fascia using the two
screws previously removed. There are two
holes in the fascia. Use the bottom hole.
8.2 To fit the closure plate baffle.
The closure plate baffle is supplied with the
fire and is intended for use where the
height of the closure plate and sealing tape
is greater than 580mm. When using the
baffle the height of the sealing tape and
closure plate can be extended to a
Page 23
©
Baxi Heating U.K. Limited 2008.
Figure 14. Fascia top location