6.
If the above test is satisfactory, open all internal connecting doors, hatches, etc. in
the room. Keep all doors and windows that open to the outside of the building closed
and recheck for spillage as above. If an extractor fan is installed in the same room as
the appliance or a connecting room, check that spillage does not occur with the fan
operating and all doors and other openings between the fan and the appliance open.
If the test is satisfactory continue with the installation.
If the test is not satisfactory
disconnect the appliance and advise the customer of the cause of failure.
10. FITTING THE FASCIA
1.
BEFORE FITTING THE FASCIA COMPLETE THE INFORMATION CONTAINED
IN THE WARRANTY AND SERVICE SECTION OF THE OWNER GUIDE (See last
pages of the OWNER guide).
2.
Detach the control knob and control bezel.
3.
Refit the fascia. The fascia top rear strip should locate in front of, but touching, the
side extensions of the engine back panel (See figure 15).
4.
Secure the fascia at the bottom
sides with the two screws previously
removed.
5.
Place the control bezel back in
position and secure it to the gas tap
bracket with two screws.
6.
Fit the control knob over the gas tap
spindle.
7.
Make sure that the ceramic fuel
effect is not dislodged when refitting
the fascia.
8.
Refit the window surround. Slide the
surround upward to locate its upper
tabs in the slots underneath the fascia
hood. Push the bottom of the surround fully against the fascia cross panel. Drop the
surround down so that the two screw heads at the back of the surround locate in the
keyholes in the cross panel.
Page 24
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2010.
Figure 15. Fascia location
Содержание 339 Heartbeat Oxysafe 2