placing the fire in position and marking the wall through the holes in the back panel.
Drill and plug the holes using no.10 wall plugs. Place the fire in position and secure
with four no.10 x 2in. woodscrews.
7.3 Gas supply connection.
8mm rigid tubing must be used to connect the gas supply to the appliance. An olive
and nut are provided for connection to the inlet “T” connector on the appliance. The
connector can be rotated to allow connection from either side or the rear. The
connector includes a valve for isolating the gas supply.
The closure plate has a cut-out for rear connection. Seal the gap between the cut-out
and the supply pipe.
Pressure check the installation pipework for gas soundness. In the United Kingdom
check in accordance with the current edition of BS6891. In the Republic of Ireland
refer to the current edition of IS 813 “Domestic gas installations”.
7.4 Fit the ceramic fuel effect and window.
1.
Place the ceramic fuel effect in position. Make
sure that it rests on the ledges at the sides of the
firebox and that its back face is touching the
horizontal rib at the back of the firebox (See figure
13).
2.
Replace the window unit. Secure the window
unit to the firebox the two screws removed
previously.
Page 21
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2010.
Figure 13. Ceramic fuel effect
location