The fireplace opening must be within the following dimensions:
1 The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
623mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance.
2 Any opening visible below the appliance may be closed in.
5.10.3
Wall mounting to conventional or pre-cast flues.
The wall opening must be within the following dimensions:
*
The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
623mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance.
The bottom of the appliance must be at least 100mm above the finished floor
covering. See figure 2. This requires the top of the opening to be at least 650mm
above the finished floor covering. Any opening visible below the appliance may be
closed in but the depth of the catchment space within the wall opening must be as
shown in figure 4.
Page 15
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2010.
Width
Height
Max.
432mm
Min.
305mm
Max.
610mm1
Min.
550mm2
Width
Height
Max.
432mm
Min.
305mm
Max.
610mm*
Min.
334mm