3
© Vallox Oy - All rights reserved
MANU
AL
Replacing the lamp
• Remove the protective glass of the lamp by moving it
to the left (Figure 3).
• Remove the lamp by pulling it to the left (Figure 4).
• Lamp type: G23 LED.
Removing and mounting the grease
filter
INSTALLATION
Use the mounting accessories included in the package
to fasten the cooker hood in place.
1. Shorten the extract air duct to be connected to the
hood (125 mm spiral duct) to the correct length.
2. Where required, install a Vallox cover strip, for
instance, (2142400 cover strip 500 or 2142500
cover strip 600) to cover the opening in the rear
wall.
3. Lift the hood so that it is in contact with the duct.
4. Fasten the cooker hood with the mounting
brackets or by other means, so that the hood is
firmly in place and cannot move (figures 1, 2 and
3). The mounting screws included in the accessory
bag are suited to walls made of wood, chipboard,
cement or stone. Use appropriate mounting
devices for other materials.
5. Check the tightness of the extract air duct system.
6. Plug the cooker hood into the mains. Ensure that
the plug can be unplugged, where required.
• Open the quick connectors of the bottom plate of
the cooker hood by turning (Figure 1).
• Turn the bottom plate down.
• Remove the grease filter from its holder (Figure 2).
1
2
3
4
1
2
4
min. 500 mm /
650 mm
3
Electrical connection
WARNING
A G23 PL lamp will cause damage!
CAUTION
The minimum distance of the
bottom edge of the grease filter to
an electric cooker is 500 mm, and
to a gas cooker 650 mm.
CAUTION
• The cooker hood must not
be connected to a flue that is
used for removing combustion
gases (e.g. from a wood- or
gas-burning fireplace, cooker,
or stove).
• The cooker hood must not
be fastened through the side
panels to the cabinets.
• Fans that are controlled
through the cooker hood must
have an engine cover and
their maximum power must not
exceed 340 W.
• Regulations on leading
extraction air outdoors must
be observed.
POWER PLUG
Timer switch
Max 4A 250V
TIMER SWITCH
Damper closed
Damper open