MOUNTING ON THE WALL
NOTE
Avoid mounting the unit on a hollow, echoing partition wall or
on a bedroom wall, or prevent the conduction of sound.
The minimum distance between the top of the unit and the
finished ceiling surface is 30 mm. Note that during mounting
the unit rises 10 mm higher than the final height.
Mount the ventilation unit on the wall with a mounting plate, as
shown in the adjacent figure. Make sure that the unit is horizontally
level after mounting.
INSTALLING THE COOKER HOOD
The cooker hood is installed on the bottom of the ventilation unit
with finger nuts (A), which are included in the accessory bag.
1. Open the bottom plate of the cooker hood, on which the grease
filter is mounted.
2. Lift the cooker hood against the bottom of the ventilation unit.
Feed the connection cord (B) at the same time inside the cooker
hood.
3. Fasten the cooker hood in place with finger nuts.
4. Pull the connection cord in place. Use line protection (C) where
required.
Observe in the figure:
1. Condensing water outlet
2. Exit hole for the condensing water outlet
3. Damper
MEASURING AND ADJUSTING THE AIR
FLOWS OF THE VENTILATION UNIT
The accessories delivered with the unit include four (4) air flow
measuring tubes. These can be inserted in the ducts to allow for
easier ventilation adjustment.
REMOVAL OF CONDENSING WATER
A
B
C
1
2
3
1
2
INS
TALLA
TION
92
1
Ø6
16
NOTE
The Vallox Silent Klick
siphon package is
delivered with the unit.
Installation instructions
for the siphon are
enclosed with the
packaging, and can
also be found online at
www.vallox.com. When
the alternative siphon
installation method is
used, the ring seal and
the locking part must
be moved to the pipe
connection part that is
mounted on the wall.
597
689
151
24
172
727
75
28
28
38
38