background image

13

© Vallox Oy - All rights reserved

CLEANING THE FANS

Check the cleanliness of the fans when servicing the filters and the 

heat recovery cell. Clean the fans as required.
You can clean the fan blades with compressed air (wear protective 

goggles) or by brushing them gently. Do not remove or move the 

fan blade balancing weights.
To clean the fan:

1.  Disconnect the ventilation unit from the mains electricity supply.

2.   Open door of the Vallox ventilation unit by undoing the finger 

screws.

3.   Lift the door off. 

CAUTION

The door is heavy.

4.  Remove the extract air filter (C), the sealing strip (E) and the 

heat recovery cell (D). See chapters “Replacing the filters” and 

“Cleaning the heat recovery cell”.

5.  Disconnect the quick connector (H) of the supply air fan (T) and/

or the extract air fan (P) cables.

6.  Push the fan cables and the rubber feed through (I) into the fan 

chamber.

7.  Remove the wing screws used to fasten the fans (J) (3 screws 

per fan).

8.  Remove the fan from the unit by pulling it forward and by tilting 

it slightly backwards at the same time.

9.  Remove the mounting screws (K) (4 screws) of the air flow 

control grille of the supply air fan and remove the grille. You 

can now clean the fan. Put the control grille back in place after 

cleaning.

10.  Reassemble in reverse order after cleaning. Ensure that the 

rubber feed throughs set in place when reinstalling the fan.

11.  Close the door. Ensure that the safety switch catch of the door 

is touching the safety switch.

12.  Plug the ventilation unit back into the mains. 

 

The fan has now been checked and cleaned.

MAINTENANCE

IMPORTANT

The fans are 

extremely sensitive 

to external shocks. It 

is recommended that 

the fans be cleaned 

in place, i.e. without 

attempting to remove 

them.
Handle the fan blades 

carefully. Do not 

remove or move the 

fan blade balancing 

weights.

T

P

D

C

E

I

T

P

H

J

J

K

S

Содержание A3741

Страница 1: ...Manual Model Vallox 101 MV Type A3741 Document D5331 Valid from 24 02 2020 Updated 05 02 2020 Ventilation unit MANUAL...

Страница 2: ...required by the alternative Vallox Silent Klick siphon installation method elbow 9 Measuring and adjusting the air flows of the ventilation unit 9 Dimensions and duct outlets 10 MAINTENANCE 11 Before...

Страница 3: ...al installations and connections must be carried out only by an electrician and in compliance with local regulations GUARANTEE The guarantee and liability exclude damage resulting from Inappropriate u...

Страница 4: ...result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor...

Страница 5: ...ws for controlling ventilation remotely also using e g a smartphone or tablet Also the unit software is updated automatically through the cloud service To connect to the cloud service the ventilation...

Страница 6: ...l in the figure MAIN PARTS Post heatingresistor in the supply air duct 8 Safety switch 9 Internal humidity sensor 10 Control panel 11 Carbon dioxide sensor optional 12 Humidity sensor optional 13 VOC...

Страница 7: ...is determines the position of the unit The top edge of the white covering strip of the ceiling mounting plate can be installed against the ceiling Alternatively a concealed mounting method can be used...

Страница 8: ...x can be accessed The distance between the service door and the ceiling mounting plate must be around 500 mm Alternatively the cables can be fed between the ceiling mounting plate and the ventilation...

Страница 9: ...ing tubes These can be inserted in the ducts to allow for easier ventilation adjustment NOTE The Vallox Silent Klick siphon package is delivered with the unit Installation instructions for the siphon...

Страница 10: ...ating resistor in the supply air duct 9 Safety switch 10 Internal humidity and carbon dioxide sensor Dimensions and duct outlets Dimensions Duct outlets R model Inner diameter of the female collar 125...

Страница 11: ...very cell clean The filter replacement interval depends on the ambient particle concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To...

Страница 12: ...rip E in place so that the strip is supported by the corner bracket G at the rear 13 Install the extract air filter C in place 14 Close the door Ensure that the safety switch catch of the door is touc...

Страница 13: ...the rubber feed through I into the fan chamber 7 Remove the wing screws used to fasten the fans J 3 screws per fan 8 Remove the fan from the unit by pulling it forward and by tilting it slightly backw...

Страница 14: ...evel in the supply air duct one duct by octave band Lw dB Sound power level in the extract air duct one duct by octave band Lw dB Adjustment position Adjustment position Adjustment position 4 14 22 33...

Страница 15: ...ignal RS_B Local hardware Modbus B signal NTC External temperature sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay inp...

Страница 16: ...ut EXTERNAL ELECTRICAL CONNECTION 3x1 5S 2x2x0 5 0 5 2x0 5 2x0 5 7028350 2014 08 29 JS 2x2x0 5 0 5 2x0 5 2x2x0 5 0 5 2x2x0 5 0 5 2x2x0 5 0 5 2x0 5 2x0 5 CAT Analog input two different functions Potent...

Страница 17: ...rd MLV control External temperature sensor NTC 4K7 MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A s...

Страница 18: ...the supply air temperature will be maintained at the level specified in the temperature setting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Ma...

Страница 19: ...ve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example ELV05006 Stig Wahlstr m K Condensing water tube Not included in the deliv...

Страница 20: ...lent Klick 3494701 14 Door 4102334 24 MyVallox humidity sensor optional 946149 5 Coarse and fine filter for supply air 978225 15 Mounting screw of the door 990712 25 MyVallox carbon dioxide sensor opt...

Страница 21: ...CONFORMITY CERTIFICATES...

Страница 22: ...22...

Страница 23: ...23 Vallox Oy All rights reserved...

Страница 24: ...D5331 04 02 2020FIN 05 02 2020ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Aftersales 358 10 7732 270...

Отзывы: