VALLOX 90K SC

THREE QUESTIONS ABOUT VENTILATION

SEASONAL CALENDAR

Autumn

• Wash or change the coarse filter and clean

or change the fine filter if needed. The
recommendation is approximately once a
year.

• Check that the heat recovery cell is clean.

• Check that the condensing water outlet is

not clogged.

• Switch summer ventilation off.

Spring:

• Wash or change the coarse filter and clean

or change the fine filter if needed.

• Clean the fan blades and the post-heating

unit if needed.

• Check that summer ventilation is in

operation.

NOTE!
For further details, see inner pages.

1.  THREE QUESTIONS ABOUT VENTILATION

1.1.  Why is air replaced in dwellings?

Good ventilation promotes healthy living for both residents and the building

. Air in a dwelling needs to

be replaced in order to remove not only humidity brought about by living but also impurities
emanating from structures and human bodies. Impurities of indoor air include carbon dioxide,
formaldehyde, radon and other gases as well as dust.
Mechanical ventilation is needed in order to be able to adjust air circulation as needed by
the residents. In a tightly sealed house, air does not circulate sufficiently by natural means.
Even in a poorly sealed house air is only replaced because of differences between indoor
and outdoor air temperatures, or because of winds. This means that ventilation is dependent
on weather conditions and cannot be regulated.
It is especially important that humidity and carbon dioxide content of the indoor air stay at
a healthy level. Recommended humidity content of good indoor air is approximately 45%.
Humidity content is lower in winter and higher in summer and autumn. Dust mites thrive in
indoor air if humidity exceeds 50%, and if humidity stays at over 60% for a long time in
winter, water will condense in the cold structures of the house and mould will start to form.
The recommended maximum carbon dioxide content in good indoor air is circa 1,000 ppm.

1.2.  What are the characteristics of adequate ventilation?

•  Indoor air stays fresh in all the rooms of the dwelling, also in bedrooms during night.

Without adequate ventilation, 

carbon dioxide content tends to rise especially in bedrooms.

• The bathroom and the sauna get dry quickly.
•  During the heating season, the windows and other outer wall structures remain dry.
•  Humidity in indoor air is not condensed in the ventilation ducts.
•  Air is fresh in the toilet as well.

1.3.  How much air is replaced?

For air to be clean to breathe, it has to be replaced with outdoor air

 every two hours.

In a new and a renovated house, air needs to be circulated continually, at least once an
hour, during the first year in order to remove harmful gases and structural humidity. In buildings
that are more than a year old and dry, ventilation can be regulated as needed. Ventilation
is boosted during for instance a sauna bath, clothes washing and cooking, and reduced
during very cold periods or when there is nobody at home.

VALLOX 90K SC dimensions and order of duct outlets, inner diameter of collar 

ø

 125 mm

82.2 117.2

157.2

157.5

345.3

82.5

114

151.5

45

MODEL L

582

345.3

151.5

45

82.9

157.5

157.2

117.2

82.5

114

MODEL R

Содержание 90k SC

Страница 1: ...nges without prior notification 1 09 347E 30 08 06 Code 3522 VALLOX INSTRUCTIONS FOR USE AND MAINTENANCE SUPPLY AND EXTRACT AIR VENTILATION WITH HEAT RECOVERY SC Code 3522 VALLOX 90K SC R 3295200 VALL...

Страница 2: ...adjustment p 4 2 2 Selection of fan speed p 4 2 3 Heat recovery bypass p 5 2 4 Air filtering p 5 2 5 Defrosting p 5 2 6 Stopping the supply air fan p 5 2 7 Outdoor air preheating p 5 2 8 Post heating...

Страница 3: ...t of the indoor air stay at a healthy level Recommended humidity content of good indoor air is approximately 45 Humidity content is lower in winter and higher in summer and autumn Dust mites thrive in...

Страница 4: ...ly pressured air in the dwelling penetrates the outer envelope of the building and between windows which may cause humidity damage during the heating season In normal conditions basic ventilation with...

Страница 5: ...s risen by circa three degrees i e to 8 C The limit of the thermostat F can be adjusted at the back of the heat recovery cell If the unit includes a preheating radiator G the supply air fan cannot be...

Страница 6: ...oothly Do not handle the filters with force When washing is done properly filters stand cleaning 3 to 4 times In other words you have to replace them at least every two years The fine filter E is not...

Страница 7: ...flow out from the ventilation unit without hindrance In connection with maintenance e g in autumn before the beginning of the heating season make sure that the condensing water outlet L in the bottom...

Страница 8: ...ing resistor see section 2 6 Defrosting on page 5 You can turn the defrost thermostat clockwise In this case there will probably be no freezing but extract air can be too warm when going out The defro...

Отзывы: